4 | Operation
10 / 20
Operating instructions sonnenBackup-Box
4 Operation
NOTICE
Using three-phase consumers in emergency operation
Damage to components/devices!
Do not switch on any three-phase (polyphase, high-voltage) electrical
consumers during emergency operation. These consumers may be dam-
aged because the sonnenBackup box only supplies electricity on one
phase.
4.1 Function
A storage system with Backup-Box automatically switches from grid to backup
operation (and vice versa). The two operating modes are described in the follow-
ing.
4.1.1 Grid operation - no grid outage
5
20
40
60
80
100
ON AL
Test
Reset
R
AL
kΩ
1
2 3
7
5
9
1
2
+
F1
SPV
2
6
3
I
0
off
off
off
4
8
3
L1
L2
L3
4
5
6
2
3
Illustration 1: Grid operation - no grid outage
1
PV system
7
Storage system
2
Inverter of the Backup-Box
8
Battery of the storage system
3
Backup-Box
9
Public electrical mains
4
Consumer connected to phase L1
5
Consumer connected to phase L2
6
Consumer connected to phase L3
In grid operation the consumers in the building (4 - 6) are connected to the pub-
lic electrical mains. All consumers in the house are supplied with electrical power.
The storage system controls - as described in the product documentation of the
storage system - the energy flows in the building.