1
S o n n e n A u s t r a l i a P t y L t d
6 0 4 S o u t h T o w e r
1-5 Railway Street, Chatswood
NSW 2067
ACN 611 337 547
0408 802 388
sonnenProtect 2500/AU
–
Update
–
Operating Instructions
This document is to be read in conjunction with KD-336 | Part no. 22009 | EN | X01. Product, instruction
and operational details supersede those printed with the sonnenProtect1300 operating instructions.
Document Number
KD-337 | Part no. 22010 | EN | X00/AU
1.2
Designation in this document Complete designation
Designation in this document
sonnenBatterie eco 8.2
Storage system
sonnenProtect 2500
sonnenProtect
eco 8.2/6, 8.2/8, 8.2/10, 8.2/12,
8.2/14, 8.2/16
Battery capacity range
2.1
Safety
Intended use
The sonnenProtect 2500 is an emergency power unit designed to
supplement the sonnenBatterie eco 8.2.
3.1
Technical Data
sonnenProtect 2500
Table 2: Technical data
System data
Maximum power (2 sec.)
2,500 W
Nominal power
2,500 W
Output voltage (AC)
240 V +/- 10 %
Nominal frequency
50 Hz
Network configuration in emergency
operation
TN-C
Operating concept
Single-phase power supply via
plug outlet and/or wired
connection. The switch to
emergency operation takes place
automatically via storage system.
Switchover time
0 sec
Dimension / Weight
Dimensions (H/W/D) in mm
235/150/124
Weight in kg
approx. 2 kg
Safety
Protection class
IEC 61009-1; AS/NZ 61009-1
Degree of protection
IP21
Protective functions
Protective functions Overcurrent
& Earth Leakage