Instructions for Assembly and Operating
SONIX 30D
OPERATING
9
General
Information
The user communicates with the device via the LCD 2 x1 6 characters
display using two push buttons for choice of functions or parameters. The
principle of operating is as follows:
-The left one 'L': choice of function or digit
-The right one 'P': change of function or value
-Left and right one at the same time 'O': acceptance the change
The menu consists of 8 basic main screens and 15 screens of user’s
functions. User default access code: 1111
CABLES SHIELDS PROBES A, B, C
CABLES SHIELDS PROBES D, E, F
PROBE A CABLE
PROBE B CABLE
PROBE C CABLE
PROBE D CABLE
PROBE E CABLE
PROBE F CABLE
AUXILIARY VOLTAGE 15V 0.1A
PULSE OUTPUT OC
CURRENT
OUTPUT
RS485
OUTPUT
Polarisation and termination
120om of the RS485 output with
both jumpers installed
FUSE T315mA
PULSE AND CURRENT OUTPUTS COMMON GROUND
ultrasonic signal
oscilloscope ground
oscilloscope trigger
Active output 0/4...20mA
Rmax < 500om
Serial digital output RS 485,
protokol MODBUS RTU,
transm. speed 1200...9600B/s
SUPPLY VOLTAGE
230V AC +10.. -15%
50Hz 10VA
ISOLATED OC
OUTPUT
Protective earth
terminal
SERVICE
CONNECTOR
15
PE
L1
N
-
+
-
C
E
C
E
+
-
24
25
26
5V
1.5k
JP13
1.5k
120
JP14
22
23
16
17
18
19
20
21
+
RS 485
15V
+
-
Flowmeter SONIX 30D
black
white
black
white
black
white
black
white
black
white
bleck
white
11
12
13
14
5
8
7
6
9
10
1
3
2
4