6
2 RM-MC1L Monitor Controller
Pin Function
Description
1
Digital Ground
0V
2
TX Output Collector
Collector of optically-isolated driver
for TX
3
REH Output Collector Collector of optically-isolated driver
for REH
4
REH Output Tally
Open collector driver active when REH
is active
5
STANDBY Remote Input Active low input to trigger STANDBY
6
CUT Remote Input
Active low input to trigger CUT
7
Digital Ground
0V
8
Digital Ground
0V
9
TX Output Emitter
Emitter of optically-isolated driver for TX
10
TX Output Tally
Open collector driver active when
TX is active
11
REH Output Emitter
Emitter of optically-isolated driver
for REH
12
TX Remote Input
Active low input to trigger TX
13
REH Remote Input
Active low input to trigger REH
14
DIM Remote Input
Active low input to trigger DIM
15
Fused Power
+12VDC @ 200mA max
Mains Power
Mains power is applied via a standard three-pin IEC male socket. Mains
voltages between 85V and 264V AC at frequencies between 47 and 63Hz
are accepted without adjustment.
A 1A, 5 x 20mm SB fuse is used. The Earth pin MUST be connected to
ensure safety.