![Sonifex Reference Monitor Meters Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/sonifex/reference-monitor-meters/reference-monitor-meters_user-handbook-manual_1321169015.webp)
Reference Monitor Meters User Handbook
5
1
FRONT PANEL INDICATORS & CONTROLS
FRONT P
ANEL INDIC
A
T
ORS & C
ONTROLS
Meter
Characteristics
Scale Range*
0dBFS
Reference
Amber Section
Starts at*
Red Section
Starts at*
Dual PPM + Standard
VU
-13 to +13dBu
+18dBu
0dBu
+8dBu
BBC PPM or EBU
PPM**
-13 to +13dBu
+18dBu
0dBu
+8dBu
Nordic PPM
-40 to +12dBu
+18dBu
0dBu
+6dBu
AES Digital PPM
-52 to 0dBFS
+18dBu
-18dBFS
0dBFS
DIN PPM
-54 to +5dBu
+18dBu
0dBu
+4dBu
Standard VU
-24 to +3VU
+18dBu
-4VU
0VU
Extended VU
-59 to +15VU
+18dBu
-4VU
0VU
German PPM
-54 to +15dBu
#+15dBu
-54dBu
+7dBu
AES Digital PPM
(SMPTE RP.0155)
-52 to 0dBFS
+18dBu
-20dBFS
0dBFS
Meter
Characteristics
Audio Input 1
Audio Input 2
SW1
SW2
SW3
SW4
SW5
SW6
SW7
SW8
Dual PPM +
Standard VU
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
BBC PPM or EBU
PPM**
ON
OFF
OFF
OFF
ON
OFF
OFF
OFF
Nordic PPM
OFF
ON
OFF
OFF
OFF
ON
OFF
OFF
AES Digital PPM
ON
ON
OFF
OFF
ON
ON
OFF
OFF
DIN PPM
OFF
OFF
ON
OFF
OFF
OFF
ON
OFF
Standard VU
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Extended VU
OFF
ON
ON
OFF
OFF
ON
ON
OFF
German PPM
ON
ON
ON
OFF
ON
ON
ON
OFF
AES Digital PPM
(SMPTE RP.0155)
OFF
OFF
OFF
ON
OFF
OFF
OFF
ON
* With 0dB of input gain selected # With 0dB input gain (SW6 and SW7 off)
**May be BBC or EBU PPM depending on the choice of scale plate.
Table 1 – Meter Characteristic DIPSwitch settings