5 Configuration Options
The Commentator Unit has several user configurable options that can be changed to suit
specific operational or personal requirements. These options can only be changed by
entering a setup mode, which is accessible when the unit is powered-up.
To enter setup mode:
apply power to the unit whilst keeping the Commentator 1 and
Commentator 2 On Air buttons pressed for 5 seconds. The power indicator LED will
flash red and amber to indicate setup mode has been entered. The Commentator 1 and
Commentator 2 On Air buttons can now be released.
The configuration options are arranged in 7 pages, with up to 7 options in each page. The
current page number is indicated on the PPM display by a single illuminated segment.
Please note, when page 6 is selected, all the segments in the PPM display are enabled to
indicate the current PPM illumination level setting. Each option within the selected page is
associated with one of the 7 main control buttons on the top panel of the unit. Each button
flashes in a recurring sequence to indicate the current mode setting of the associated
option. One flash equals mode 1, two flashes equals mode 2 etc. Buttons that do not have
an associated option in the current page do not flash.
To change the current page:
press and hold the Commentator 3 On Air button for at least
1 second. The PPM display will change to indicate the new page.
To change the option mode setting:
press the appropriate button once. The number of
flashes will increase to indicate the new mode setting. Once the maximum option mode
setting has been reached, the value will wrap around to mode 1.
The configuration option settings for each page are listed below. The factory default
settings for each option are shown in brackets:
Configuration option settings for page 1
Commentator 1 ON AIR button:
Mode 1 Commentator 1 ON AIR is permanently disabled and cannot be selected.
Mode 2 Commentator 1 ON AIR can be selected as normal (default).
Mode 3 Commentator 1 ON AIR is permanently selected and cannot be disabled.
Commentator 1 TALKBACK A button:
Mode 1 Commentator 1 TALKBACK A button momentary mode enabled (default).
Mode 2 Commentator 1 TALKBACK A button latching mode enabled.
Mode 3 Commentator 1 TALKBACK A button momentary and latching modes enabled.
Commentator 1 TALKBACK B button:
Mode 1 Commentator 1 TALKBACK B button momentary mode enabled (default).
Mode 2 Commentator 1 TALKBACK B button latching mode enabled.
Mode 3 Commentator 1 TALKBACK B button momentary and latching modes enabled.
Содержание CM-CU21
Страница 1: ...CM CU21 Commentator Unit User Handbook...
Страница 29: ...CM CU21 Commentator Unit User Handbook 19 N OT E S NOTES...
Страница 30: ...20 CM CU21 Commentator Unit User Handbook NOTES N OT E S...
Страница 31: ...CM CU21 Commentator Unit User Handbook 21 NOTES N OT E S...
Страница 32: ...w w w sonifex co uk t 44 0 1933 650 700 f 44 0 1933 650 726 sales sonifex co uk...