9
CM-CU1 Configuration Options 1
CM-CU1 Configuration Options
The CM-CU1 has several user configurable options that can be changed to
suit specific operational or personal requirements. These options can only
be changed by entering a setup mode, which is accessible when the unit is
powered-up.
Entering Setup Mode
Apply power to the unit whilst keeping the TALKBACK A and TALKBACK B
buttons pressed for 5 seconds. The power indicator LED will flash red and
amber to indicate that Setup Mode has been entered. The TALKBACK A and
TALKBACK B buttons can now be released.
The configuration options are arranged in 7 pages, with up to 5 options in
each page. The current page number is indicated on the PPM display by a
single illuminated segment, e.g. segment 5 illuminated means that you are
on Page 5.
Each option within the selected page is associated with one of the 5 main
control buttons on the top panel of the unit. Each button flashes in a
recurring sequence to indicate the current mode setting of the associated
option. One flash equals mode 1, two flashes equals mode 2 etc. Buttons
that do not have an associated option in the current page do not flash.
Please Note:
when Page 6 is selected, all the segments in the PPM display
are enabled to indicate the current PPM illumination level setting.
Changing The Current Page
Press and hold the ON AIR button for at least 1 second. The PPM display will
change to indicate the new page.
Changing The Option Mode Setting
Press the appropriate button once. The number of flashes increases to
indicate the new mode setting. Once the maximum option mode setting
has been reached, the value wraps around to mode 1.
The configuration option settings for each page are listed below. The factory
default settings for each option are shown in brackets:
Config Page 1 - ON AIR Button Enable/Disable & TALKBACK
Button Latching Modes
ON AIR button:
Mode 1
ON AIR is permanently disabled and cannot be selected.
Mode 2
ON AIR can be selected as normal (default).
Mode 3
ON AIR is permanently selected and cannot be disabled.
TALKBACK A button:
Mode 1
TALKBACK A button momentary mode enabled (default).
Mode 2
TALKBACK A button latching mode enabled.
Mode 3
TALKBACK A button momentary and latching modes enabled.
TALKBACK B button:
Mode 1
TALKBACK B button momentary mode enabled (default).
Mode 2
TALKBACK B button latching mode enabled.
Mode 3
TALKBACK B button momentary and latching modes enabled.
TALKBACK C button:
Mode 1
TALKBACK C button momentary mode enabled (default).
Mode 2
TALKBACK C button latching mode enabled.
Mode 3
TALKBACK C button momentary and latching modes enabled.
TALKBACK D button:
Mode 1
TALKBACK D button momentary mode enabled (default).
Mode 2
TALKBACK D button latching mode enabled.
Mode 3
TALKBACK D button momentary and latching modes enabled.
Please Note:
Momentary mode button operation – press to activate, release to
deactivate. Latching mode button operation – press once to activate, press
again to deactivate. Momentary and latching mode button operation - for
momentary press the button for less than 0.25 sec, for latching press for
more than 0.25 sec.
Содержание CM-CU1
Страница 12: ...2 1 CM CU1 System Diagram Fig 1 2 CM CU1 Commentator Unit Block Diagram...
Страница 26: ...16 2 CM CU21 System Diagram Fig 2 2 CM CU21 Commentator Unit Block Diagram...
Страница 43: ...Notes...
Страница 44: ...www sonifex co uk t 44 0 1933 650 700 f 44 0 1933 650 726 sales sonifex co uk...