Functions and Features 

Note: The device is design to meet the IEEE802.3af standard. 

 
The SonicWALL PoE Injector adds 48VDC to the unused (non-
data) wires in standard Category 5 Ethernet cable. As a result, 
the Power over LAN Hub delivers both data and power to the 
terminal. 
 

EMC Compliance:

 Category 5 foiled twisted-pair cables must be 

used to ensure compliance with requirements of FCC Part 15, 
subpart B, Class B. The use of unshielded cables (Category 5 for 
10BASE-T ports or for 100BASE-Tx ports) complies with Class A 
requirements.  
 

Installation 

The PoE Injector may be free standing or wall mounted using the 
back wall holders. 
 

Before You Install 

Before you mount the PoE Injector to a fixed location: 

  Do not cover the PoE Injector or block the airflow to it with any 

other objects.  

  Keep the PoE Injector away from excessive heat and humidity, 

and free from vibration and dust. 

  Be sure the cable length from the Ethernet network source to 

the terminal does not exceed 100 meters (333 Feet). The PoE 
Injector is not a repeater and does not amplify the Ethernet 
data signal  

 

Installing the Unit 

  Connect the PoE Injector to an AC outlet (100-240 VAC), using 

a standard power cord. 

 Connect

 

the unit 

Data In

 jack (input) to the Ethernet network 

and the 

Data & Power Out

 jack (output) to the terminal. 

 
 
 

 
 
 
 
 
 
 
 
 
 
Figure 1: Illustration of connectivity for the PoE Injector. 
 

NOTE: There is no “on-off” switch. Simply plug the PoE 
Injector into an AC power source.

 

 

 

Indicators 

 

 indicates that the power is on

steady green

 

-

 

Led

 

Main

 
 

 

terminal is connected

 indicates that the 

steady green

 

-

Led 

 

Active

 (Power is active). 

 

 

 

Specifications 

 

Environmental Specifications 

 

Mode

 

Temperature

 

Humidity

 

Operating

 

0 to 50 °C

 

32 to 122°F

 

10 to 90% 
(no condensation allowed)

 

Storage

 

-20 to 70 °C

 

-4 to 158°F

 

10 to 90% 
(no condensation allowed)

 

 

Electrical Specifications 

 

Input Voltage

 

90 to 264 VAC 
(47-63 Hz)

 

Input Current at 110 VAC

 

Input Current at 220 VAC

 

0.34 ampere (max)

 

0.17 ampere (max)

 

Minimum Available Output Power

 15.4 Watts

 

 

 

Nominal Output Voltage

 

45 to 56 VDC

 

 

Ethernet Interface 

 

Input (Data In): 

 

Ethernet 10/100Base-T

 

RJ 45 female socket

 

Output (Data & Power Out): 

 

Ethernet 10/100Base-T, plus 
48 VDC

 

RJ 45 female socket, with 
DC voltage on wire pairs 
7-8 and 4-5. 

 

 

 

  

Troubleshooting Tips 

  Be sure AC power is applied to the PoE Injector, using 

an operational AC cable with an appropriate ground 
connection. 

  Use standard 4 pair (8 wires) UTP or FTP CAT5 cable. 

  Do not use a “crossover” type Ethernet cable. 

  Be sure the input Ethernet cable is connected to the 

Data In

 port. 

  Be sure the output Ethernet cable is connected to the 

Data & Power Out

 port. 

  Verify that the Ethernet cable length is less than 333 feet 

(100 meters) from the Ethernet source to the load. 

  Verify that a power-ready Ethernet compatible device is 

connected. 

  Verify that the cables and RJ-45 connectors have a tight 

connection and there is not a “short” over the cables or 
connectors. 

Safety Information 

Important Safety Information 

  Installation and removal of the PoE Injector must be 

carried out by qualified personnel only.  

AC Power Cord Set:

 

  The power cord must have regulatory agency 

approval for the specific country in which it is 
used (i.e., UL, CSA, VDE, etc.).  

  The power cord must be a three-conductor 

type (two current carrying conductors; one 
ground conductor) terminated on one end by 
an IEC 60320 appliance coupler (for 
connection to the PoE Injector), and on the 
other end by a plug containing a ground 
(earthing) contact.  

  The power cord must be rated for a minimum 

of 250VAC RMS operation, with a minimum 
rated current capacity of 5 amps (or a 
minimum wire gauge of 18 AWG (0.75mm

2

). 

Note: PoE Injector units installed in Australia 
require power cords with a minimum wire 
gauge of 16 AWG (1.0 mm

2

). 

  The AC wall socket-outlet must be near the PoE Injector 

and easily accessible. You can remove AC power from 
the PoE Injector by disconnecting the AC power cord 
from either the wall outlet or the PoE Injector coupler.  

  The PoE Injector data and data/power interfaces are 

qualified as SELV (Safety Extra-Low Voltage) circuits 
according to IEC 60950. These interfaces can only be 
connected to SELV interfaces on other equipment.  

 

Port Input

 

Power Output

 

Terminal

 

Ethernet

 

 

Отзывы: