PAT-80
● PAT-85 ● PAT-86 – USER MANUAL
86
13.4 Measurement of leakage current
Substitute leakage current
Range
Resolution
Basic uncertainty
0.00 mA...3.99 mA
0.01 mA
(5% m.v. + 2 digits)
4.0 mA...19.9 mA
0.1 mA
Influencing factor
Designation
Additional uncertainty
Position
E
1
0%
Supply voltage
E
2
0%
Temperature
E
3
0.075% / ºC
opening voltage: 25 V...50 V
internal resistance of the testing device 2 kΩ ± 20%
adjustable upper limit in the range of: 0.01 mA... 19.90 mA with resolution of 0.01 mA
adjustable measuring time in the range of: 1 s…60 s with resolution of 1 s and option
Con-
tinuous test
PE leakage current
In the half-time of the measurement, the tester automatically changes the polarity of
the test socket and as a final result it displays the value of higher leakage current.
Range
Resolution
Basic uncertainty
0.00 mA...3.99 mA
0.01 mA
(5% m.v. + 2 digits)
4.0 mA...19.9 mA
0.1 mA
Influencing factor
Designation
Additional uncertainty
Position
E
1
0%
Supply voltage
E
2
0%
Temperature
E
3
0.1% / ºC
Power consumption of the
tested appliance
E
4
0%
Low frequency magnetic field
E
5
0%
The shape of the network
voltage (CF)
E
8
0%
test voltage from mains
adjustable upper limit in the range of: 0.01 mA... 19.90 mA with resolution of 0.01 mA
adjustable measuring time in the range of: 1 s…60 s with resolution of 1 s and option
Con-
tinuous test
Содержание PAT-80