Remote  control  via  GSM  that  works  by  sending  and  receiving  SMS  (configurable  in  2  languages,  Spanish  / 
English). Ability to operate powered 12V ideal photovoltaic installations.

TELKAN 1 GSM 

Telephonic Control Via GSM  Code:19.077

Manual of installation and use

230V~ +10% -15%  50Hz   max. 2VA

 DESCRIPTION

Power supply

on  

Z

 in alarm

off  

Z

 Without alarm

 LED´s 

 SIM card

Application 

(relay)

5A 250V~ SPST. Relay with free voltage-contact (operation as a switch)

Input for temperature probe

Connection for temperature probe PTC2000 (-40°C ... + 140°C). When the 
probe detects that the temperature has crossed the threshold defined by 
the user, the controller sends an SMS alarm only to phone number that has 
been activate INFO function. (F. MEET, can activate the desired relay).

on  

Z

 relay connected

off  

Z

 relay disconnected

  

r1 

(Relay) 

External antenna connector

Connection for external antenna with magnetic base

 Contact closure alarms

When open / close contact for more than 5 seconds generates an alarm

a1 

(Alarm) 

on          

Z

 in  temperature alarm

off          

Z

 without temperature alarm

blinking 

Z

 Connection error

t1 

(Probe)

Input for external battery

External input for a sealed lead battery of 12V and a 
capacity of 1.2 to 20Ah.

on  

Z

 power supply by battery

off  

Z

 power supply by 230V~

on  

Z

 powered supply

off  

Z

 without power supply

on          

Z

 wiht signal GSM

off          

Z

 without signal GSM

blinking 

Z

 sending dates or

                             SMS received

on          

Z

 inserted and operational

off          

Z

 without card SIM

blinking 

Z

 the card has PIN 

  (take out of TELKAN & disabled the PIN)

b1 

(Battery)

PWR 

(Power supply)

GSM 

(Signal)

SIM 

(Card)

 Button ON / OFF

Connect / disconnect the relays manually without sending message.

R1

R2

A1

A2

T1

T2

C1

B1

BAT

PWR GSM

SIM

SIM

R1

R2

RELAY

ON/OFF

TELKAN

GSM

by Sonder

TELKAN

GSM

by Sonder

L

230V~

N

SIM

ANTENNA

L

N

Contact Alarm

Temperature Probe

PTC2000

T1

A1

+

-

Battery

B1

5A

R1

C

NO

SIM:

 Works with prepaid card or contract of any company, it is recommended the prepaid for save money. Before 

purchasing the SIM, verify what company has the better coverage in the area. (SIM not included)

1 Input for external battery

: When detecting a change of power (battery passes network or vice versa) sends 

SMS warning of network failure and SMS of service restoration. (Battery not supplied, code: 7.190)

1 Relay 5A

: You can activate/deactivate manually or by SMS, activate /deactivate timed and query the status of 

the relay.

1 Input for T Probe:

 allows receive warnings of a temperature alarm, the relay can be linked to temperature 

alarm and view the history of temperatures for the last 4 hours via SMS. (Probes not supplied, code: 4.343)

1 Alarm contact

: When open / close contact for more than 5 seconds will generate an alarm.

IP65 Box

: Box for surface mounting. (Box not supplied, code: 4.914)

Before  giving  the  power  to  the  control,  remove  the  SIM  card  PIN  and  insert  it  into  the  TELKAN

START UP

3

3

1

1

- Measures: Rail-DIN box 4 modules (90x70x58 mm)

- Independent dispositive

- Free-voltage contact relay
- Wiring type: H05VV-F or H05RR-F

- Power supply:  230V~   +10% -15%  50/60Hz  max. 2VA

2     

2

- Minimum section for cable of: Relay 

Z

 

 2,5 mm  Power supply 

Z

 

1 mm  

- According normative:  

EN 60730 / EN 301511 / EN 301489-1 / EN 301489-7

- Contamination degree:  clean environment

- Software classe A - Action type 1.B

-  Environment: Temperature 

Z

 

0°C to 45°C / Humidity 

Z

 

20% to 85% 

TECHNICAL SPECIFICATIONS

Electrical drawing:

230V~

5 - Connect the control to the power supply  230V~

2 - Check with a mobile phone the SIM (which has no access PIN code, the credit,  

sending and receiving SMS).

1 - Install the control away from contactors, motors ... etc. 

It may be the case with 

some  contactor  with  strong  electromagnetic  peaks  need  to  install  a  relay 
between the output of TELKAN and the contactor coil.

4 - make the rest of connections.

3 - Insert SIM in 

TELKAN

.

4

4

BAT

PWR GSM

SIM

BAT

PWR GSM

SIM

BAT

PWR GSM

SIM

5

5

IP20

If the installation was successful should light the LEDs: 

PWR

SIM

 and 

GSM

Cardholder to insert a MiniSIM that is 
operational  and  any  company.  Does 
not  work  with  MiniSIM  card  or  the 
phone number doubled. 

Do not insert 

or  remove  the  SIM  card  with  the 
Sondertel powered.

OPERATING TEMPERATURE ALARM

30°C

31°C

29°C

Temperature

Device is 

out 

of alarm

Device is 

inside 

the alarm

Delays are very useful to discriminate when a temperature alarm of a product load in cold rooms where there are short peaks and temperature are controlled. 

First off set the temperature for alarm for example 30°C ± 1°C (differential of activation) may also indicate the time that has to remain above or below to consider that is in alarm. 
You can define two different values or the same for the delay time (Delay). Factory goes to 0 and alerts at the same time the temperature goes from temp alarm ± 1°C. 

5 min.

Actives  the  alarm  in  case  of  being  more  than  5  minutes  (time  delay)  above  31°C 
(temperature alarm + differential) and does not disable the alarm until it is below of 
29°C over 5 minutes (temperature alarm - differential)

0000 alarm t1 30     

delays 5 minutes for activation and deactivation

Temperature for alarm: 30°C  + fixed Dif.: ± 1°C

0000 delay t1 5

SMS

We decline any responsibility for damaged equipment result

- Equipment whose serial number has been damaged,

- Devices whose deterioration is the result of impact or liquid

Reserved the right to change without prior notice.

This device has 3 year warranty according to the date of manufacture, 

it is limited to replacement of faulty part. Transport not included.

of poor handling. Not included in the warranty:

deleted or modified.
- Devices whose connection or use has not been executed
according to the instructions accompanying the appliance.
- Apparatus modified without the consent of the manufacturer.

or gaseous emanations.

For the rest of general conditions visit our web.

CONDITIONS OF GUARANTEE

SONDER

Cod.:7259 INGV4 ENE19

delay for activation 5 and 10 minutes for deactivation 

0000 delay t1 5 10

- Send an wrong SMS to the 

TELKAN 

from a phone that had 

previously made valid orders.

- The 

TELKAN 

saves the last 5 phone numbers that have given a correct order and if they make a lost call, the TELKAN sends an SMS of state, but the SMS that an alarm has 

occurred only is sent to the numbers set in INFORM function. 

- The temperature exceeds the limit set by the user

Alarm: T1
T1: 33.5C
A1: off
B1: MAIN

ERROR: invalid language. 0-Castellano, 1-English.

- If a request to change languages includes an invalid number

T1: 26.8C
A1: off
B1: MAIN

- Message received periodically according to set time with 

the function 

Alive 

activated

IN CASE OF:

SMS received

- If the SMS received by the 

TELKAN 

not start with numeric digits and comes from an unknown telephone is interpreted as a message from the phone company:

         • If the control is configured with the function PROMO in on, the SMS is forwarding to all phones set in Function Inofrm 
         • If the control is configured with the function PROMO in off, is deleted.

pwrd +
on - relay on
off - relay off
inform on - receive alarm
test - status
pass xxxx - change password

Probe set for alarm
Reading probe alarm
Disconnected alarm contact
Main power supply

Temperature read by probe T1
Alarm 1 off
Main power supply

Example:

Control  device  for  DIN  rail  mounting  and 
connection via fixed pipeline.

Very important:

When  installing  control  ensure  you  have  good 
coverage  away  from  contactors  and  other 
signals that may interfere.

Device  designed  for  a  situation  of  pollution 
clean.

This control is not a safety device, and can not be 
used  as  such,  it  is  the  installer  responsibility 
incorporate adequate protection to every type 
of installation (

HOMOLOGATED

- Make a call to 

TELKAN 

from a phone that had previously 

made valid orders.

R1: on
T1: 26.8C
A1: off
B1: BATT (11.799V)

Must comply with 2 factors: Tempe Time Set

Password (set from factory to 0000) + followed by the command:
order - (meaning that order)

SMS 

Status query

:

State relays
Current temperature read by probes
Alarm status
battery connected (value of charge)

Warning! The volatge of 
the battery is very low.
BATT (9.112V)

-  Message  received  when  the  control  detects  that  the 

battery power is low.

Warning low battery with charge value

OK

MiniSIM

MicroSIM NanoSIM

Sonder Regulación, S.A.

Avda. La Llana, 93 

08191 RUBÍ

(Barcelona) Spain

www.sonder.es