3. Lubricate the O-rings; see
Section 8.5.2 "Endcap O-Rings"
4. Position the transducer endcap next to the transponder housing.
5. Connect the white transducer endcap cable to the white connection block.
6. Connect the battery disconnect fob connector (if fitted) to the black connection block.
7. Connect the battery connector to the black connection block.
Note
Observe the position of the transducer cable, ensure the cable does not become trapped when
inserting the transducer.
8. Slowly rotate the transducer to coil the cable inside the bulkhead plate; push the transducer into
the housing taking care not to trap the cable.
9. Position the clamp rings in the grooves on the endcap.
10. Position the guard with the bump stop over the transducer.
11. Rotate the clamp rings
, if necessary, to align the holes with the screw ends of the guard
;
see
Figure 8–7 Refitting the Guard and Bump Stop
12. Lift the end of the transponder enough to locate the guard screws through the holes in the clamp
rings.