![SONARAY WP-5040 Скачать руководство пользователя страница 1](http://html.mh-extra.com/html/sonaray/wp-5040/wp-5040_installation-manual_1319884001.webp)
PRODUCT
PHOTO
MODEL
NUMBER
WP-5040
WP-5060
WP-5080
WP-5100
WP-5120
WP-5150
POWER
CONSUMPTION
40W
60W
80W
100W
120W
150W
OPERATING
VOLTAGE
100-277V AC ~ 50/60Hz
HOUSING
MATERIAL
Aluminum
OPERATING
TEMPERATURE
-20°C ~ +50°C / -4°F ~ +122°F
IP
RATING
65
DIMENSIONS
14.56 x 9.05 x 7.48
18.30 x 9.29 x 8.97
Non Cutoff Wall Pack Light Installation Guide
ATTENTION
INSTALLATION PREPERATION
1. Take out the luminaire from the box and place it on a level platform for easy installation.
2. For proper operation, a qualified electrician should perform the installation.
3. Ensure the normal ambient temperature of the installation location is between -20°C ~ +50°C.
4. Ensure the voltage of the luminaire is capatable with the onsite voltage before installation.
5. Any luminaire with damaged power cord should not be installed.
Note: The power must be cut off before installation.
TECHNICAL PARAMETERS
REV: 21 0101 0000
TYPE
DATE
PROJECT
NOTES
www.sonarayled.com
®
©2021 | SONARAY LED LIGHTING HEADQUARTERS | 34 LAKEVIEW COURT VERONA, VA 24482 USA | OFFICE 844.202.5606 | FAX 540.242.7221
This manual instructs the important information of installation and operation. Be sure to strictly follow
the instructions before use. To ensure correct installation and operation of the product, carefully read
and understand all contents of this guide. Any mechanical or electrical modifications to the product
will void warranty and may cause dangerous hazards. To avoid potential issues caused by high
temperature, be sure no objects are on the lens while the product is switched on.
SITUATION
POSSIBLE REASON
POSSIBLE SOLUTION
LED
DOES NOT
LIGHT UP
Incorrect input wiring
Confirm wire colors
No power to the luminaire
Recycle power or check power connection
Incorrect voltage
Confirm voltage
LED
FLICKER
Poor power connection
Check power connection
Input voltage fluctation
Confirm voltage
TROUBLESHOOTING
GENERAL MAINTENANCE
Make sure there is no power running to the luminaire when performing maintenance.
The lens and the housing can be cleaned using a soft cloth without any corrosive material.