background image

6

Multiple Source/Multiple Zone with Paging (Figure 5)

Features
• 1 Zone is HIGH POWER with Bridged Outputs and IR Control
• 2 Zones are STEREO with Volume Controls
• 4 Zones are MONO with Impedance Matching Volume Controls and Paging
• 1 Zone is STEREO with Volume Control and Paging
• AUX Input for KSU Paging in Selected Zones

This configuration shows several rooms in stereo mode while
utilizing mono in selected areas. Note that certain areas receive
the paging signal. Due to its large size, the master bedroom
receives a bridged 4 channels providing 60 watts per channel  .

Major Corporate System (Figure 6)

Features
• Automatic 2 source Main Music
• 8 Speakers on 2 Channels with Impedance Matching Volume Controls and

MONO Function

• 4 Zone Keypad System
• Executive Office controls with option to select from Main Source to Local 
• AC Power Control of Main Music Sources
• Key Switch On/Off of Entire System, Auto-On Feature Defeated, 12v control

for AC Switching

• AUX Input for KSU Paging in Selected Areas

A specialized installation that includes remote key switch turn
on and usage of multi-zone controllers for individual spaces
with keypad controls. Executive suite is specialized with
main/local source selection and control of entire system.
Restrooms, small vestibules, elevators, and large rooms
arranged in multiple seating areas are some examples of spaces
more appropriate to monaural music. Each of the Sonamp
1230’s 12 channels may be individually configured for monau-
ral reproduction if required to achieve smooth coverage of the
entire musical content of the source.

A Basic Six Zone System (Figure 7)

Features
• 6 Rooms
• 3 Music Sources
• 3 Video Sources
•  Sonance Navigator Master keypads at each zone

This diagram depicts a basic six zone install featuring a
Sonance Navigator Harbor with three audio and three video
inputs feeding a Sonamp 1230 amplifier with voltage turn on,
as well as feeding video to three TVs located in zones two, five
and six.Each of the six zones is controlled by a Sonance Navigator
Master keypad. The source components are controlled by the
Harbor’s Common IR outputs. When only a couple source com-
ponents are present,the 200VA switched power outlet can be used
to power up these devices. A voltage controlled power strip to
power up more source components is recommended to prevent
overloading of the switched AC outlet. The Control Output of
the Harbor should be used to control the power strip. (Do not
exceed the 100mA rating of the Control Output.)

MAINTAINING YOUR SONAMP 1230

The Sonamp® 1230 does not require periodic maintenance and
has no user serviceable parts inside. Do not remove the top
cover as this will increase your risk of electric shock. To keep
the amplifier clean, use only a soft cloth and never use any
solvents or abrasives. Fingerprints may be removed with a soft
cloth moistened only with a few drops of water.

SPECIFICATIONS

All Channels Driven

Output Power, Stereo mode, RMS: 30 Watts per channel, 12 channels @8

45 Watts per channel, 12 channels @4

60 Watts per channel, 6 channels @8

bridged

IHF: Dynamic Power:

49 Watts per channel, 12 channels @8

78 Watts per channel,12 channels @4

158 Watts per channel, 6 channels @8

bridged

Dynamic Headroom:

+2.13dB, 12 channels @8

+2.38dB, 12 channels @4

+4.15dB, 6 channels @8

bridged

Total Harmonic Distortion:

0.1% 20Hz-20kHz @8

(30 WRMS)

0.25% 20Hz-20kHz @4

(45 WRMS)

THD @ 1kHz less than 0.01% with 8

(30 WRMS)

THD @ 1kHz less than 0.01% with 4

(45 WRMS)

I.M. Distortion (SMPTE 4:1) @8

: 0.01% @ 30 Watts

Signal to Noise Ratio:

-100dB below rated output (A-weighted)

Input Sensitivity:

700 millivolt for 30 watts RMS @8

Input Impedance:

20k

Power Consumption:

1440 Watts, maximum 4

full power

6.5 Watts, standby

AC Fuse

15A AG

Optional Items

3-space Rack Mount Faceplate 

Dimensions:

10-1/2" x 16-3/4" x 18"

(267mm x 425mm x 457mm)

38 lbs (17KG)

10A AG

16-3/4" x 5-3/4" x 15-3/8" 
(425mm x 146mm x 391mm)

1400 Watts maximum @ 4 ohms, full power  

RMF Dimensions:      19" x 5-1/4" x 15-3/8" 
                                   (483mm x 133mm x 391mm) 
 
Shipping Weight:        38 lbs (17kg) 

Содержание SONAMP Sonamp 1230

Страница 1: ...n to cords at plugs conve nience receptacles and the point where they exit from the appliance 14 Cleaning The appliance should be cleaned only as recommended by the manufacturer 15 Non Use Periods The...

Страница 2: ...e Silver MediaLinQ OFC Interconnects Speaker wires These may be unterminated tinned bare wire at connections or spade banana or pin connectors Gold plated connectors are preferred to resist oxidation...

Страница 3: ...Fire Hazard Use Only Same Type And Rating Fuses Disconnect Power Supply Before Changing Fuse Do Not Expose This Unit To Rain Or Moisture No User Servicable Parts Inside See Operating Manual Before Us...

Страница 4: ...red Place tape over the VC hole to prevent tampering Power Trigger Controls The Sonamp 1230 may be automatically activated by an input signal low voltage trigger or manual pushbutton It also provides...

Страница 5: ...o speakers one pair of speakers per room The factory default rear panel DIP switches and toggles are set for this application This is a single zone system Note that each room may have a volume control...

Страница 6: ...urn on as well as feeding video to three TVs located in zones two five andsix Eachof thesixzonesiscontrolledbyaSonanceNavigator Master keypad The source components are controlled by the Harbor s Commo...

Страница 7: ...the package Ship the packaged unit to Technical Assistance Department Sonance 212 Avenida Fabricante San Clemente CA 92672 7531 WARRANTY COVERAGE USA ONLY If within one 1 year from the date shown on t...

Страница 8: ...ng Manual Before Using Mise en garde Afin d viter toute possibilit d incendie n utiliser que le m me type de fusibles D brancher l appareil avant de changer les fusibles Ne pas exposer cet appareil l...

Страница 9: ...nual Before Using Mise en garde Afin d viter toute possibilit d incendie n utiliser que le m me type de fusibles D brancher l appareil avant de changer les fusibles Ne pas exposer cet appareil l ire o...

Страница 10: ...Operating Manual Before Using Mise en garde Afin d viter toute possibilit d incendie n utiliser que le m me type de fusibles D brancher l appareil avant de changer les fusibles Ne pas exposer cet appa...

Страница 11: ...de changer les fusibles Ne pas exposer cet appareil l ire ou l humidit Ne pas ouvrir l appareil Lire attentivement la notice avant utilisation SONAMP 1230 CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN S...

Страница 12: ...it Ne pas ouvrir l appareil Lire attentivement la notice avant utilisation SONAMP 1230 CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN SN SONANCE SAN CLEMENTE CA 92672 7531 FUSE FUSE VOLUME VOLUME VOLUME V...

Отзывы: