Ph: 8613857402537
2. When ACC ON: the device turns on GPS, 4G
module, MCU wakes up.
How the device wakes up: Any alarm signal of the
built-in G-sensor will wake up the device.
Note:
This command is valid when ACCCTLGNSS, 1 #
Default: MODE, 21,2200 # is the factory default
working mode of the device. And real time ping is
10second
4
Timing reporting mode:
Mode, 1, T1, ..., T5, D #
Mode, 1, T1 #
Mode1, T1, T2, D #
The time of device wake up and report, the format of
T1-T5 is: HHMM stands for 24-hour hour and
minute, D is the reporting period, and the default is 1
for daily reporting, [1, 31].
Example:
MODE, 1,0800,1314,2 #
It means device will wake up at 8:00 and 13:14 every
2 days.
5
Periodic reporting mode:
MODE, 3, T #
T = [5, 1440], The range of T.
Unit: minute
T is the gap time for MODE 3 reporting.
6
Real-time tracking mode:
MODE, 2, T #
T = [5,999], The range or T.
Unit: second
Default value: 10
The position reporting period when the device is
moving.
4.2 Application Notes on Low Power Alarm
Table 4.2 Application Notes on Low Power Alarm
1
Low battery alarm command
LOWW, V, N #
V: a 3-digit integer, the third digit
is the number after the decimal
point;
N: 0/1
If the voltage of the equipment is lower than LOW
30S, a low power alarm will be reported, and it will
be reported once after device is turned on;
N = 0: execute current working mode
N = 1: if it is MODE2, forcibly switch to MODE, 1
Default: LOWW, 360,0 #