FIXING THE UNIT TO THE WALL
1.
Mount the fan to the wall so as to reach the switch (4). Do not fix it higher than 1,8 m.
2.
Choose such studs which are conform to the wall bearing capacity and weight of fan.
3.
Considering the size of studs, drill two holes in the wall horizontally, 14 cm from each
other.
4.
Place the studs to the holes. Screw in the screws so as to have the head of the screws in
0,5 cm distance from the wall.
5.
Hang on the fan to the screws, let it down, then move it to the right till stop.
6.
Check if the fan is stable fixed on the wall.
7.
Only connect it to the mains after that.
FEATURES
23 cm blade diameter
•
adjustable output (3 stages)
•
adjustable tilt angle of head (90°)
•
wall or desk location
•
white
THE FAN OPERATION
Fan can be switched on and desired air speed can be adjusted with the rotary switch (4). After the off state (0), the first switchable
stage is the highest grade III. By turning the switch further to the right, speed can be reduced to stage II or I. Dip angle of the head
can be adjusted simply, there's no need to loosen or fasten any screws. When the appliance set to its base, it can be set from the
horizontal up to the totally vertical position, it can stand totally in 5 position.
CLEANING
In order to ensure optimum functioning, the unit may require cleaning at least once a month, depending on the manner of use and
degree of contamination.
1.
Prior to cleaning switch off and power off the unit by unplugging it from the electric outlet!
2.
Use a slightly moistened cloth to clean the unit's exterior. Do not use any aggressive cleaners. Avoid getting water inside of and
on the electric components of the appliance!
3.
Install the fan again!
TROUBLESHOOTING
TECHNICAL SPECIFICATION
power supply: . . . . . . . . . . . . . . . . . . . . . . . . . . . . 230 V ~ / 50 Hz / 50 W
protection class: . . . . . . . . . . . . . . . . . . . . . . . . . . . II.
3
maximum fan - air mass volume: . . . . . . . . . . . . . . . F = 13,22 m /min
fan input power: . . . . . . . . . . . . . . . . . . . . . . . . . . . P = 34,0 W
3
service value: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SV = 0,39 (m /min)/W
power consumption in standby position: . . . . . . . . . P = 0,0 W
SB
noise level: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . L = 55,65 dB(A)
WA
maximum air speed: . . . . . . . . . . . . . . . . . . . . . . . . c = 4,7 m/sec
service value standard: . . . . . . . . . . . . . . . . . . . . . . IEC 60879:1986 (corr. 1992)
length of power cable: . . . . . . . . . . . . . . . . . . . . . . . 1,3 m
fan blade diameter: . . . . . . . . . . . . . . . . . . . . . . . . . 23 cm
dimensions: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 x 28 x 17 cm
ventilator weight:. . . . . . . . . . . . . . . . . . . . . . . . . . . 1,6 kg
Malfunction
Possible solution
The fan doesn't turn on.
Check the power supply
!
Check the switch
!