SOMNOmedics SOMNOtouch RESP Скачать руководство пользователя страница 13

 

 

13 

 

10.

 

Contact 

For all questions, problems and suggestions please contact us via telephone or fax. We assure a quick 
and qualified advice and handling of all your enquiries. 
 
 
 
 
 

 
 

 

 

 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 

*If due to technical difficulties our staff is not available, you will be redirected to our mail box. If that 
is the case, please leave your name and telephone number so that we can call you back as soon as 
possible.

 

You can send us important information any time by fax:  

+49 (0) 9 31 / 35 90 94 49 

Our telephone hotline assures you professional help and advice during the day:  

  9:00  

  17:00        +49 (0) 9 31 / 35 90 94 0 

Our  mobile  phone  hotline  provides  a  high  level  of  support  with  urgent  technical 

problems*: 

  7:00   

    9:00

        

+49 (0) 1 72 / 6 75 69 90 

17:00   

  24:00

        

+49 (0) 1 72 / 6 75 69 90 

With the Service-Login on our website 

www.somnomedics.de

 you get free access to 

the latest software updates. 

We also provide service and support via E-Mail: 

[email protected]

 

Содержание SOMNOtouch RESP

Страница 1: ...MANUAL Miniaturized Pneumotachograph for SOMNOtouch RESP SOMNOmedics GmbH Am Sonnenstuhl 63 D 97236 Randersacker Tel 49 931 35 90 94 0 Fax 49 931 35 90 94 49 E Mail info somnomedics de Internet www so...

Страница 2: ...2 SOMNOmedics GmbH Am Sonnenstuhl 63 D 97236 Randersacker Tel 49 931 35 90 94 0 Fax 49 931 35 90 94 49 E Mail info somnomedics de Internet www somnomedics de Rev 1 01 08 2014...

Страница 3: ...ts 2 Intended use 4 3 Functionality 4 4 Safety note 4 5 Initializing the measurement 5 6 Attaching the senor 7 7 Calibration procedure 8 8 Adjusting the analysis 11 9 Cleaning and disinfection 12 10 C...

Страница 4: ...pstream of the pneumotachograph is higher than the air pressure downstream By measuring this pressure drop with a differential pressure sensor the respiratory flow can be determined 4 Safety note This...

Страница 5: ...the following view in the montage selection Figure 1 montage selection in the advanced mode By clicking the Application plans button which is at the bottom of the window a document will open This doc...

Страница 6: ...6 Figure 3 signal overview when selecting the two necessary sensors...

Страница 7: ...tube 5 5 Connect the opposite end of the pneumotachograph 4 black Luer lock to the mask via the CPAP oxygen adapter 7 6 Use the CPAP pressure tubes 8 to connect pneumotachograph 4 and the differentia...

Страница 8: ...lue is displayed the mentioned offset To eliminate this offset click with the right mouse button on the channel description PT flow to open the context menu Figure 5 Confirm Zero Point Calibration wit...

Страница 9: ...lease enter the volume of the used calibration pump and confirm with OK The PT flow curve is rescaled according to the defined tidal volume Figure 7 Meassurement with a 500ml calibration pump Figure 8...

Страница 10: ...with the new calibration values in the input window Figure 10 Then the tidal volume analysis data are updated and displayed according to the adjusted calibration as shown in Figure 11 Figure 10 confir...

Страница 11: ...be set Breath Threshold for definition of the beginning and the end of the breath Min Breath Strength Average Window Hypo and Hyperventilation Max leakage specify for the report mask selection Edit ma...

Страница 12: ...sensor TOS150 Wipe disinfection For example Terralin Liquid Mikrozid AF Tuch Ready to use Ready to use 5 min 5 min After use Remove adhesives if necessary Follow manufacturer s instructions Silicon tu...

Страница 13: ...all you back as soon as possible You can send us important information any time by fax 49 0 9 31 35 90 94 49 Our telephone hotline assures you professional help and advice during the day 9 00 17 00 49...