SOLIRIS Uno

2

2 x

Connect the wires to the termi-
nals of the connecting bracket
in accordance with the terminal
layout (chapter 2.2).

Press the safety cover onto the
back of the bracket then fit this
one on the recessed box.

To remove the safety cover, use a screw-
driver to press gently in the slot provided in-
side the terminal block.

Plug the SOLIRIS Uno control
unit into the bracket, together
with the cover frame.

When setting (chapter 3) and
programming (chapter 4) is
completed, the cover plate can
be clipped onto the control unit.

Terminal layout

2.2

N

L

N

Soliris Uno connecting 

Bracket

Terminal layout

 Main Phase 

(L   )

 Main Neutral   

(N   )

 Motor Neutral 

(N)

 Motor Up 

(

)

 Motor Down 

(

)

N is bridged

internally

Common          (C)
Sun sensor      (    )
Wind sensor    (    )
Rain sensor     (    )

C

Mounting

2.1

Test:

When operating power has been connected, the direction of

the motor can be tested using the 

and 

buttons.

Soliris sensor

Rain sensor

Soliris Uno

4 x 0,75 mm

2

2 x 0,75 mm

2

3 x 0,75 mm

2

Supply

3 x 1,5 mm

2

Supply

3 x 1,5 mm

2

We reserve the right to make changes due to technical improvements. 

SOLIRIS Uno is suitable for mounting in a 60 mm Ø concealed connection box or suitable surface mounting cap (Somfy accessories).

N

L

N

C

SUPPLY

230V 50Hz

Phase

Neutral

Earth

LT motor

DOWN

PE

N

UP

Soliris sensor

Soliris uno

C

Rain sensor

brown

brown

blue

blue

yellow/green

Содержание SOLIRIS Uno

Страница 1: ...possible and the sun function can be switched off If the wind is too strong the awning blind is automatically retracted and manual operation is blocked The wind function is a safety function and is always activated 220 240V 50 60Hz IP 40 II 5 C to 40 C dry living areas cos 0 8 3A 230V 50Hz Setting up testing commissioning and troubleshooting for this equipment should only be car ried out by a trai...

Страница 2: ... N L N Soliris Uno connecting Bracket Terminal layout Main Phase L Main Neutral N Motor Neutral N Motor Up Motor Down N is bridged internally Common C Sun sensor Wind sensor Rain sensor C Mounting 2 1 Test When operating power has been connected the direction of the motor can be tested using the and buttons Soliris sensor Rain sensor Soliris Uno 4x0 75mm 2 2x0 75mm 2 3x0 75mm 2 Supply 3x1 5mm2 Sup...

Страница 3: ...ted threshold When the wind speed exceeds the threshold set on the SOLIRIS Uno the red LED lights on and the awning is retracted after 2 seconds When the wind speed falls be low the threshold setting the red LED begins to blink A manual control can be given after 30 seconds and an automatic sun control can be given after 12 minutes after 12 min after 30 sec Wind control operation WIND Wind speed s...

Страница 4: ...the blind awning to its highest position retracted Once the blind awning is in its final position retracted the relay must have switched off either automatically after 3 minutes or press the button Mode of operation 4 1 In awning mode each time or is pressed this constitutes a move command This mode is set by default in factory Programming awning mode Press for approx 2 seconds The red and yellow ...

Страница 5: ... been programmed chapter 4 2 1 Set the venetian blind at its UP limit position blind retracted 2 Press The blind will move to the intermediate position the slats are closed 3 Press and simultaneously After approx 3 seconds the slats will momentarily move UP and the LED shines green 4 Adjust the right tiliting angle using and 5 Press for approx 2 seconds The green LED light off the slat tilting pro...

Страница 6: ...y Then press and simultaneously until the red LED lights up 4 times twice briefly pause twice briefly EU venetian blind demo is programmed MODE 4 4 3 Demo setting venetian blind US In the US blind demo setting each time or are pressed briefly this constitutes one long move command and if they are held down for a longer time this constitutes a short move command A slat tilting operation can be prog...

Отзывы: