Closing end stops
Stops fixed securely to the ground should stop the travel of the gate leaves when closing.
The opening stops are integrated into the motor (see page 18).
Mechanical lock
If the gate is equipped with a mechanical locks, it must be removed.
Pillars
The pillars must have a robust structure and be at least 21 cm wide. If they do not, improvements may have to be made to your pillar to
guarantee correct installation and to ensure that the bracket stays in place.
It is not recommended to mount the bracket level with the pillar: risk of spalling.
Electrical pre-equipment
• Linking of cells: 2 x 0.75 mm² cable
• Other accessories: see page 22
Cable feed
• For cell cables, pass a sleeve over each pillar.
• Underground cables must be equipped with a protective
sheath with a sufficient diameter to contain all the cables.
• Fit a 230 V electrical input as close as possible to the
control unit.
Côté Propriété
Côté Chaussée
Cellule réceptrice
Cellule émettrice
Receiver cell
Pavement side
Property side
Top view
Transmitter cell
Flexible ICT sheath
The cables are not supplied with the product.
Cables required
• Power supply: 3 x 1.5 mm² cable or 3 x 2.5 mm² for outdoor
use (type H07RN-F minimum)
• Connection between the motors: 2 x 1 mm² cable;
fit a IP 55 junction box to protect the connection between
the cable leaving the motor and the extension which goes
to the control unit.
Provision must be made for the supply cable to be fed through according to the electrical standards in force in the country of use.
If a cable conduit cannot be made, use a cable grommet which will withstand the passage of vehicles (ref. 2400484).
Motor cable
Extension to the control unit
Содержание SGS 501