Copyright © 2010 Somfy SAS. All rights reserved.
SGH io
16
EN
Radio frequency
868-870 MHz io-homecontrol® bidirectional, tri-band
Power supply
230 V ~ 50 Hz
Operating temperature
- 20 °C to + 70 °C
Protection rating
IP 44
Maximum number of connected io control
points
9
Safety level
Category I
TECHNICAL DATA
9.
Problems with the SGH io?
8.2.
Observations
Possible causes
Solutions
The roller shutter is
not operational.
The wiring is incorrect.
Check the wiring and modify if
necessary.
The motor's overheating protection has
tripped.
Wait for the motor to cool down.
An incorrect cable has been used.
Check the cable used and ensure it
has 3 leads.
The Somfy io control point battery is
low.
Check if the battery is weak and
replace it if necessary.
The control point is not compatible.
Check the compatibility and replace
the control point if necessary.
The Somfy io control point used has not
been programmed into the motor.
Use a programmed io control point
or program this io control point.
The roller shutter
stops too soon.
The crown is incorrectly positioned.
Fit the crown correctly.
The end limits have been incorrectly set. Readjust the end limits.
The roller shutter does
not move to oriented
slat position [favourite
position (my)].
Faulty "slats flat" setting.
Adjust the "slats flat" position.
8.3. Restoring the original configuration
This reset deletes all control points, sensors, and all
end limits settings and resets the motor's direction of
rotation and favourite position (my).
Apply the double power cut only for the motor to be
reset!
1) Set the roller shutter to the halfway position (if possible).
2) Cut the power supply off for 2 seconds.
3) Switch the power supply back on for 5 to 15 seconds.
4) Cut the power supply off for 2 seconds.
5) Switch the power supply back on: The roller shutter
makes a movement for a few seconds.
If the roller shutter is in the upper or lower end limit
position, it will make a brief movement.
6) Press and hold the PROG button: the roller shutter
makes a first movement then a second movement a few
moments later. The motor is now configured with original
settings.
Repeat the procedures in chapter "
-
Commissioning
".
2 sec.
2 sec.
15 sec.
5 sec.
1
6
5
3
2
4
OFF
OFF
ON
ON
my
Содержание SGH io