2020 SOMFY ACTIVITES SA. All rights reserved.
P3
Photoelectric cell safety input
Comments
P3 = 2: the auto-test is run on the device for each operating cycle via power supply
switching.
WARNING! Installation of photoelectric cells WITH AUTO-TEST P3=2 is
mandatory if:
•
remote control of the mechanism is used when the door is not visible,
•
automatic closing is activated (
P0 = 2 or 3
).
P3 = 4: the safety input is not taken into account
WARNING! If P3=4, operation of the motorisation in automatic mode is prohibited
and control of the motorisation by sight is mandatory.
7
PROGRAMMING THE REMOTE CONTROLS
7.1
Memorising 2 or 4-button remote controls
NOTICE
If this procedure is carried out using a button which has already been memorised, the button will be cleared.
1]
Press the “
PROG
” button for 2 s.
ð
The “PROG” indicator light is permanently lit.
NOTICE
Pressing “PROG” again allows the next function to be memorised (230 V aux output control)
2]
Press the outer left- and right-hand buttons on the remote control simultaneously until the indicator
light flashes.
3]
Press the button selected to control the function (complete opening, Aux 230 V output control).
ð
The “PROG” indicator light flashes for 5 s.
Complete opening control
Aux 230 V output control
> > > Illustration 22
7.2
Memorising 3-button remote controls
> > > Illustration 23
NOTICE
If this procedure is carried out using a remote control which has already been memorised, the remote con-
trol will be cleared.
1]
Press the “
PROG
” button for 2 s.
ð
The “PROG” indicator light is permanently lit.
NOTICE
Pressing “PROG” again allows the next function to be memorised (230 V aux output control)
2]
Press "
PROG
" at the back of the remote control.
ð
The “PROG” indicator light flashes for 5 s.