3 Electrical connection
Only a qualified electrician (VDE 1000 -10 [Association of German Engineers]) may set up, test, commission and
perform troubleshooting on the installation.
Switch off the voltage to all of the connection lines which are to be installed.
Take safety precautions to prevent the installation from being switched on unintentionally.
Exposed power lines
→
Risk if contact is made, electric shock.
-Switch off the voltage to all of the connection lines which are to be installed.
-Take safety precautions to prevent the installation from being switched on unintentionally.
Somfy shall not be liable for any defects or damages caused by the failure to observe this installation guide.
Somfy hereby declares that this product conforms to the essential requirements and other relevant provisions of
Directive 2014/35/E. A declaration of conformity is available on the website www.somfy.com/CE.
230 V ~ 50/60 Hz
1,5 mm
2
PE N L
0,75 mm
2
0,75 mm
2
1,5 mm
2
Motor
DC RTS receiver
Centralis DC IB
S51 switch
Output line
24 V DC
(red = +
black = _)
black
red
24 V DC RTS motors are supplied directly from the power supply
Note: Observe the relevant installation guides
(e.g. relating to polarity) when connecting
the motors/control units.
SOMFY ACTIVITÉS SA
50 avenue du Nouveau Monde
74300 CLUSES, FRANCE
www.somfy.com
SOMFY ACTIVITÉS SA, Société Anonyme, capital 35.000.000 Euros, RCS Annecy, 303.970.230 - 03/2018