![background image](http://html.mh-extra.com/html/somfy/pergola/pergola_connection-and-quickstart-manual_1317490001.webp)
Copyright © Somfy SAS 7/2019 P-0036
Pergola Tilt RTS Control Box
Connection Quick Start Guide
Switch 1
ON
Drive with coder sensor
OFF
Drive without coder sensor
Switch 2
(only if switch 1 is set to ON)
ON
Activates synchronization S1 and S2
OFF
Deactivates synchronization S1 and S2
Switch 3
ON
5.5 A max. per output
OFF
3 A max. per output
Switch 4
ON
Activates the temperature sensor
OFF
Deactivates the temperature sensor
Switch 5
ON
Closing in the event of wind
OFF
Opening in the event of wind
Power Supply Input
A
-
24 Vdc power supply input (SELV)
B
+
Drive output 1
Blue
C
-
24 Vdc - 3A/5.5A drive: Maximum
current according to switch 3
Brown
D
+
Drive output 2
Blue
E
-
24 Vdc - 3A/5.5A drive: Maximum
current according to switch 3
Brown
F
+
Rain Sensor
O
Contact
Dry contact input
P
Common
Q
-
Power supply output:
24 Vdc/- 300 mA
R
+
DESCRIPTION & CONNECTIONS
S
T
External
antenna
PROG
button.
OUTPUT Vdc
S1
+
-
OUTPUT Vdc
POWER SUPPLY
+
-
OUTPUT Vdc
+
-
+
-
S2
+
-
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
Switch 1
Switch 2
Switch 3
Switch 4
Switch 5
O P
Q
R
Output
Power
supply
Rain
sensor
B
A
Drive
output S2
Drive
output S1
D
ri
ve
w
ithou
t
en
co
der
F
E
D
C
Power
supply
input
External antenna
S
Signal
Conductor
T
GND
Shielding braid
OUTPUT Vdc
S1
+
-
OUTPUT Vdc
POWER SUPPLY
+
-
OUTPUT Vdc
+
-
+
-
S2
+
-
Status
The LED flashes every 4 seconds: Circuit board waiting.
The LED flashes rapidly: Command in progress.
OUTPUT Vdc
S1
+
-
OUTPUT Vdc
POWER SUPPLY
+
-
OUTPUT Vdc
+
-
+
-
S2
+
-
Fault
The red LED light remains illuminated for 5 seconds: Current consumption threshold has
been exceeded or circuit board has heated up too much during an output command.
The red LED flashes: drive synchronisation fault.
The orange LED remains illuminated for several seconds: Backing-up the memory.
The orange LED flashes rapidly: Movement of a drive not permitted by a sensor action.
OUTPUT Vdc
S1
+
-
OUTPUT Vdc
POWER SUPPLY
+
-
OUTPUT Vdc
+
-
+
-
S2
+
-
Wind
(1)
The orange LED remains illuminated: Wind
threshold has been exceeded.
The orange LED flashes rapidly: protection still
in progress for 15 minutes after the threshold
last being exceeded.
OUTPUT Vdc
S1
+
-
OUTPUT Vdc
POWER SUPPLY
+
-
OUTPUT Vdc
+
-
+
-
S2
+
-
Temperature
(1) (2)
The orange LED remains illuminated: the ice threshold has been
exceeded.
The orange LED flashes rapidly: protection still in progress for 15
minutes after the latest threshold is exceeded.
DESCRIPTIONS OF CIRCUIT BOARD INDICATOR LIGHTS
1
2
3
4
S
T
Rain
(1) (2)
The orange LED remains illuminated: The rain threshold has been
exceeded.
The orange LED flashes rapidly: protection still in progress for 15
minutes after the threshold last being exceeded.
OUTPUT Vdc
S1
+
-
OUTPUT Vdc
POWER SUPPLY
+
-
OUTPUT Vdc
+
-
+
-
S2
+
-
BEFORE YOU BEGIN:
Power must be cut before wiring or making any wiring changes
OUTPUT Vdc
S1
+
-
OUTPUT Vdc
POWER SUPPLY
+
-
OUTPUT Vdc
+
-
+
-
S2
+
-
Status
Fault
Wind
Rain
Temperature