manualshive.com logo in svg
background image

Copyright © Somfy SAS 7/2019                                                           P-0036

Pergola Tilt RTS Control Box

Connection Quick Start Guide

Switch 1

ON

Drive with coder sensor

OFF

Drive without coder sensor

Switch 2

 

(only if switch 1 is set to ON)

ON

Activates synchronization S1 and S2

OFF

Deactivates synchronization S1 and S2

Switch 3

ON

5.5 A max. per output

OFF

3 A max. per output

Switch 4

ON

Activates the temperature sensor

OFF

Deactivates the temperature sensor

Switch 5

ON

Closing in the event of wind

OFF

Opening in the event of wind

Power Supply Input

 A 

-

24 Vdc power supply input (SELV)

 B 

+

Drive output 1

Blue

 C 

-

24 Vdc - 3A/5.5A drive: Maximum 

current according to switch 3 

Brown

 D 

+

Drive output 2

Blue

 E 

-

24 Vdc - 3A/5.5A drive: Maximum 

current according to switch 3 

Brown

 F 

+

Rain Sensor

 O 

Contact

Dry contact input

 P 

Common

 Q 

-

Power supply output:  
24 Vdc/- 300 mA

 R 

+

DESCRIPTION & CONNECTIONS

 S 

 T 

External 

antenna

PROG 

button.

OUTPUT Vdc

S1

+

-

OUTPUT Vdc

POWER SUPPLY

+

-

OUTPUT Vdc

+

-

+

-

S2

+

-

ON
ON
ON
ON
ON

OFF
OFF
OFF
OFF
OFF

Switch 1

Switch 2

Switch 3

Switch 4

Switch 5

 O  P 

 Q 

 R 

Output

Power 

supply

Rain 

sensor

 B 

 A 

Drive 

output S2

Drive 

output S1

D

ri

ve

 w

ithou

en

co

der

 F 

 E 

 D 

 C 

Power 

supply 

input

External antenna

 S 

Signal

Conductor

 T 

GND

Shielding braid

OUTPUT Vdc

S1

+

-

OUTPUT Vdc

POWER SUPPLY

+

-

OUTPUT Vdc

+

-

+

-

S2

+

-

Status

The LED flashes every 4 seconds: Circuit board waiting.
The LED flashes rapidly: Command in progress.

OUTPUT Vdc

S1

+

-

OUTPUT Vdc

POWER SUPPLY

+

-

OUTPUT Vdc

+

-

+

-

S2

+

-

Fault

The red LED light remains illuminated for 5 seconds: Current consumption threshold has 

been exceeded or circuit board has heated up too much during an output command.
The red LED flashes: drive synchronisation fault.
The orange LED remains illuminated for several seconds: Backing-up the memory.
The orange LED flashes rapidly: Movement of a drive not permitted by a sensor action.

OUTPUT Vdc

S1

+

-

OUTPUT Vdc

POWER SUPPLY

+

-

OUTPUT Vdc

+

-

+

-

S2

+

-

Wind 

(1)

The orange LED remains illuminated: Wind 

threshold has been exceeded.

The orange LED flashes rapidly: protection still 

in progress for 15 minutes after the threshold 

last being exceeded.

OUTPUT Vdc

S1

+

-

OUTPUT Vdc

POWER SUPPLY

+

-

OUTPUT Vdc

+

-

+

-

S2

+

-

Temperature 

(1) (2)

The orange LED remains illuminated: the ice threshold has been 

exceeded.
The orange LED flashes rapidly: protection still in progress for 15 

minutes after the latest threshold is exceeded.

DESCRIPTIONS OF CIRCUIT BOARD INDICATOR LIGHTS

1

2

3

4

 S 

 T 

Rain 

(1) (2)

The orange LED remains illuminated: The rain threshold has been 

exceeded.
The orange LED flashes rapidly: protection still in progress for 15 

minutes after the threshold last being exceeded.

OUTPUT Vdc

S1

+

-

OUTPUT Vdc

POWER SUPPLY

+

-

OUTPUT Vdc

+

-

+

-

S2

+

-

BEFORE YOU BEGIN: 

Power must be cut before wiring or making any wiring changes

OUTPUT Vdc

S1

+

-

OUTPUT Vdc

POWER SUPPLY

+

-

OUTPUT Vdc

+

-

+

-

S2

+

-

Status
Fault
Wind
Rain
Temperature

Отзывы: