2.4. TIPS AND RECOMMENDATIONS FOR INSTALLATION
2.4.1. Questions about the Glydea Ultra?
Observations
Possible causes
Solutions
The motorised product does
not operate.
The wiring is incorrect.
Check and reconnect the power supply
The control point is not
compatible.
Check for compatibility and replace the
control point if necessary.
2.4.2. Erasing the memory of the motor (Fig G)
Press the S button until the motorised product moves 3 times.
All the settings are erased.
2.3.2. Modifying the drive rotation direction
1) Press the S button to reverse the rotation direction.
Green LED ON = Open/CCW, Green LED blinking = Open/CW
2) Press the M button to confirm the change and go to the next step. The red light is on.
2.3.3. Back release setting
Move the curtain to the OPEN (UP) end limit
1) Press the S button in sequencing mode to adjust the back release position.
2) Press the M button to confirm the new back release position.
The LED flashes alternatively from green to red and the curtain starts to open and close.
2.3.4. SILENT or HI-SPEED mode
On the motor you can switch from the silent mode to the Hi-speed mode by sliding the “selector” from SILENT to
Hi-SPEED.
In silent mode, the motor speed is 7.5cm/s. And in hi speed mode, the speed can be adjustable, refer 2.3.5
for details.
2.3.5. Speed setting
1) Press the S button to switch the speed from 12.5 cm/s - 15 cm/s (default speed) - 17.5 cm/s - 20
cm/s and back to 12,5 cm/S
2) Press the M button to confirm and go back to direction setting.The green LED is on or blinking.
3.1. OPEN AND CLOSE BUTTONS
(Fig H)
Pressing the Open or Close button fully opens or closes the motorised product.
3.2. STOP FUNCTION
(Fig I)
The motorised product is moving.
Briefly press Stop: the motorised product stops automatically.
3.3. TIPS AND RECOMMENDATIONS FOR USE
3.3.1. Questions about the Glydea Ultra?
If the motorised product still does not work, contact a motorisation and home automation professional.
3. USE AND MAINTENANCE
This drive is maintenance-free
Observations
Possible causes
Solutions
The motorised product
does not operate.
The motorisation is in thermal protection mode.
Wait for the motor to cool down.
4. TECHNICAL DATA
Power supply
100V - 240V
Operating temperature
0°C to + 60°C
Index protection rating
IP 30
Safety level
Class I
Содержание Glydea Ultra WT
Страница 100: ...100 Copyright 2017 SOMFY ACTIVITES SA Soci t Anonyme All rights reserved 6 5 4 3 2 1 F x3 G 1 2 H I...
Страница 101: ...Copyright 2017 SOMFY ACTIVITES SA Soci t Anonyme All rights reserved 101...
Страница 102: ...102 Copyright 2017 SOMFY ACTIVITES SA Soci t Anonyme All rights reserved...
Страница 103: ...Copyright 2017 SOMFY ACTIVITES SA Soci t Anonyme All rights reserved 103...