background image

10

Rollixo io

Diagnosis

Safety 

brake

Diagnosis

Safety brake not connected or no connection to the connector between 5 and 6. Safety brake 

activated (when connected between 5 and 6)

Consequences 

No movement at all possible

Actions

Check the safety brake connection

Motor

Diagnosis 

Motor not properly connected

Consequences 

No movement at all possible

Actions 

Check the motor connection

Diagnosis

Safety brake activated (if safety brake is connected between the blue wire of the motor)

Consequences 

No movement at all possible

Actions 

Check the installation and replace the safety brake

Diagnosis 

Thermal motor protection switched on

Consequences 

No movement at all possible

Actions 

Wait approximately 10 minutes

Diagnosis 

Motor defective or fuse blown

Consequences 

No movement at all possible and flush lighting not on

Actions 

Check the condition of the fusing and replace if required (spare fuse supplied). Replace the 

motor if it is still not working

Motor

Diagnosis 

Waiting for motor adjustment

Actions 

Adjust the motor end points

Status of the LED

Meaning

   

LED is off

Installation working

 

 

LED flashes slowly

Waiting for an action or setting

 

 

LED flashes quickly

Detection/activation working

 

LED stays on

Failure/defect in the installation

Rollixo io

Содержание 1841166

Страница 1: ...Rollixo io Installation manual for rolling doors ...

Страница 2: ...ing end limits 5 Connection optical safety edge 5 Connection photocells 6 Connection reflex photocells 6 Alarm 7 Activating deactivating the alarm 7 Operation of the alarm 7 Testing of the alarm 7 Programming the remote controls 8 Type of remote controls 8 Programming the remote controls 8 Programming the Keygo io remote controls 8 Removing a Keygo io remote control 8 Removing all remote controls ...

Страница 3: ...for external programming 3 4 2 1 Prog STOP 1 2 3 6 7 8 9 5 4 Fixation of the Rollixo receiver Installation Make sure there is a plug socket at a suitable distance mains cable supplied 2 m We advise installing the receiver on the same side of the door as the safety edge transmitter Remove the flush lighting cover Unscrew the receiver cover and remove it Mark the drill holes Fix the receiver to the ...

Страница 4: ... the UP button Press the UP button Product goes upwards OK Product goes upwards OK Product goes downwards NOT OK go to step 2 Product goes downwards NOT OK step 2 again the motor moves to and fro LED 1 flashes slowly the product goes upwards Release at the upper position Adjust if necessary with the and buttons See the Somfy manual for setting the Somfy motor See the Simu manual for setting the Si...

Страница 5: ... 1 Prog STOP 3 4 2 1 Prog STOP 3 4 2 1 Prog STOP Press the and buttons at the same time and or the button until the motor moves to and fro LED 1 goes out or 5 Confirm end limits Connection optical safety edge Brown Brown Brown White White White Green Green Green See the Somfy manual for setting the Somfy motor See the Simu manual for setting the Simu motor or L1 L2 N M 1 2 3 4 L1 L2 N M 1 2 3 4 ...

Страница 6: ...nnection reflex photocells 1 2 14 15 17 TX RX 1 2 3 18 16 5 19 TX RX 24V dc 24V Cell Sec Cell Test Sec h 16 17 18 19 20 14 15 Brown Blue 14 15 Black Grey 19 20 24V dc 24V Cell Sec Cell Test Sec h 16 17 18 19 20 14 15 Rollixo io Rollixo io ...

Страница 7: ...kly The alarm sounds a beep if it is switched on The alarm sounds briefly to show that it is active Operation of the alarm The alarm sounds for 2 minutes if the door is manually lifted or in case of obstacle detection cable sabotage No movement of the door is possible for as long as the alarm is sounding If the alarm sounds press a button on a programmed remote control in the receiver to stop the ...

Страница 8: ...the movement and confirm its proper completion Keytis io 3 4 2 1 Prog STOP 3 4 2 1 Prog STOP 3 4 2 1 Prog STOP Press the button of the receiver until the LED above it continuously lights up the LED above the button flashes the remote control is programmed in the receiver LED flashes At the same time press until Within a maximum of 10 minutes press a button of the remote control to be programmed Cl...

Страница 9: ...ing the work modes Lock programming buttons Unlock programming buttons To unlock the programming buttons repeat the abovementioned locking procedure At the same time press the STOP and Prog button of the receiver until all LEDS flash The programming buttons are now locked Dipswitch information Dipswitch Possible setting ON OFF 1 Self test photocells Activated Deactivated 2 Choice of cell type Phot...

Страница 10: ...Actions Check the installation and replace the safety brake Diagnosis Thermal motor protection switched on Consequences No movement at all possible Actions Wait approximately 10 minutes Diagnosis Motor defective or fuse blown Consequences No movement at all possible and flush lighting not on Actions Check the condition of the fusing and replace if required spare fuse supplied Replace the motor if ...

Страница 11: ...e controls to be installed 30 Connections Mains cable 2 m IEC plug phase zero earth Flush lighting E14 max 15 W 230 V Safety inputs 3 inputs for n Wired contact strip optical resistance n Safety brake n Photoelectric cells Self test output for safety systems For cells Input wired operation Dead contact NO sequential operation Orange light 24 V max 4 W Output alarm siren Yes Operation Operating key...

Страница 12: ...12 SOMFY NL Oktober 2017 Somfy Ltd Moorfield Road Yeadon Leeds West Yorkshire LS19 7BN 0113 391 3030 sales uk somfy com www somfy co uk ...

Отзывы: