31
9.3.
Power terminal block (terminal block X4)
L, N, PE power supply 1 x 230 V TN-S
1, 2, 3
drive motor phases
S
shealding of motor cable - connected with ground
PE
ground of motor cable
4
shealding of cable IRC sensor
5, 8
power supply of IRC sensor
6, 7
output signal from IRC sensor
10.
Control panel
10.1.
Key switch
Keys switch on control panel in position 0 = buttons “Open” and “Close” not active,
eventually not active also external inputs see setting DIP 5 point 5.2
In case of activation of fire detectors - switch on and switch off = reset of alarm
10.2.
Descriptions of control panel
OPEN
= button open gate
STOP
= button stop, by continuous pressing for 10 seconds is
activated reset of fire detectors
CLOSE
= button to close gate
On control panel of FSTronic there is installed keyboard with buttons OPEN, STOP, CLOSE. On the
keyboard there are also LED diodes, which display all current states of the control. This enables
the gate operator to determine particular states and potential gate alarms.
Содержание FSTronic IRC-FI
Страница 36: ...www somati system cz 36 12 2 FSTronic IRC FI CONTROL BOARD DPS ...
Страница 37: ...www somati system cz 37 12 3 FSTronic IRC FI Motor with IRC sensor IRC sensor motor White Yellow Green brown ...
Страница 38: ...www somati system cz 38 12 4 FSTronic IRC FI CONNECTION OF FIRE DETECTORS ...
Страница 39: ...www somati system cz 39 12 5 FSTronic IRC FI Connection aof additional battery module ...
Страница 42: ...www somati system cz 42 GridScan PRO SY 2000 FSS GridScan PRO SY 2000 LO ...
Страница 43: ...www somati system cz 43 GridScan MINI FSS GridScan MINI PNP NPN ...