71
Active LED
Performance (%)
LED Green
0 (Standby)
LED Green + 1 LED Yellow
0 - 25
LED Green + 2 LED Yellow
25 - 50
LED Green + 3 LED Yellow
50 - 75
LED Green + 4 LED Yellow
75 - 100
Table 4 - Performance of the pump
Figure 57 - Performance of the pump
Note:
the pump is configured as standard at full capacity (75-100%).
Changing the setting of the pump
Can be chosen between the the view of the performance of pump and th view of
settings, just press the button once.
If you need to change the pump performance, you must press the button for 2 seconds
(Figure 58), after this action the LEDs start blinking, then you must press the button
until the desired setting (Table 5), after 10 seconds the display automatically switches
to the view of performance with alteration saved.
Figure 58 - Pump settings