background image

MBUS-M13 - User manual

Table 2 –

Continued from previous page

Abbreviation

Meaning

RAM

Random Access Memory

REQ_UD

Request User Data (Class 1 or 2)

RFC

Requests For Comments

RSP_UD

Respond User Data

RSSI

Received Signal Strength Indicator

RTC

Real-Time Clock

RTOS

Real-Time Operating System

RTS

Request to send

RTU

Remote Terminal Unit

S0

S0 interface (pulse interface, EN 62053-31)

SCADA

Supervisory Control and Data Acquisition

SCP

Secure Copy

SFTP

SSH File Transfer Protocol

SIM

Subscriber Identity Module

SML

Smart Message Language

SMTP

Simple Mail Transfer Protocol

SND_NKE

Send Link Reset

SND_UD

Send User Data to slave

SNTP

Simple Network Time Protocol

SPST

Single Pole Single Throw Relay (closing switch)

SRD

Short Range Device

SSH

Secure Shell

SSL

Secure Sockets Layer

TCP

Transmission Control Protocol

THT

Through-Hole Technology

TLS

Transport Layer Security

U

Unit width of the housing (1 U = 18 mm)

UART

Universal Asynchronous Receiver Transmitter

UDP

User Datagram Protocol

UL

Unit load for M-Bus

UMTS

Universal Mobile Telecommunications System

UTC

Universal Time Coordinated

VDE

Verband der Elektrotechnik Elektronik Informationstechnik e.V., German association

VHF

Very high frequency

VIF

Value information field

VIFE

Value information field extensions

VLAN

Virtual Local Area Network

VPN

Virtual Private Network

WAN

Wide Area Network

WLAN

Wireless Local Area Network

wM-Bus

Wireless Meter-Bus (EN 13757, part 3, 4 and 7)

XML

eXtensible Markup Language

XSLT

eXtensible Stylesheet Language Transformation

Table 2: Abbreviations

Page 8/18
UG_EN_MBUS-M13.pdf

Version: 1.09

Released

Frank Richter, 6 December 2022

© solvimus GmbH

Содержание MBUS-M13 Series

Страница 1: ...Module Version 1 09 Date 6 December 2022 Authors Remo Reichel Frank Richter solvimus GmbH Ratsteichstr 5 98693 Ilmenau Germany solvimus GmbH Ratsteichstr 5 98693 Ilmenau Germany Telephone 49 3677 7613...

Страница 2: ...MBUS M13 User manual Page intentionally left blank Page 2 18 UG_EN_MBUS M13 pdf Version 1 09 Released Frank Richter 6 December 2022 solvimus GmbH...

Страница 3: ...6 2 Introducing the device 9 2 1 General information 9 2 2 Structure of the module 9 2 3 Delivery variants 9 2 4 Connectors 10 2 4 1 Terminals at the edge for pin headers 10 2 4 2 Connector X1 11 2 4...

Страница 4: ...on is intended exclusively for qualified electricians or persons instructed by these They must all have good knowledge in the following areas Applicable standards Use of electronic devices 1 2 4 Inten...

Страница 5: ...her information References to additional literature manuals data sheets and internet pages 1 4 Font conventions Names of paths and files are marked in italics According to the system the notation is u...

Страница 6: ...truction of control cabinets must be observed The components are populated with electronic parts which can be destroyed by an electrostatic discharge When handling the components ensure that everythin...

Страница 7: ...Protocol Secure I2C Inter Integrated Circuit I O Input Output ICMP Internet Control Message Protocol ID Identification Identifier unique marking IEC International Electrotechnical Commission IEEE Inst...

Страница 8: ...hort Range Device SSH Secure Shell SSL Secure Sockets Layer TCP Transmission Control Protocol THT Through Hole Technology TLS Transport Layer Security U Unit width of the housing 1 U 18 mm UART Univer...

Страница 9: ...for the connection The following figure shows the module Figure 1 The module MBUS M13 The module integrates all necessary components for the operation of the M Bus The internal power supply generates...

Страница 10: ...M13 S 500325 MBUS M13 G 500327 MBUS M13 M 500328 Available upon request Table 3 Delivery variants Variants with population are available upon request 2 4 Connectors The module MBUS M13 is connected v...

Страница 11: ...tage and current modulation to transmit data The master transmits telegrams by modulating the bus voltage the slave transmits telegrams by modulating the current through the bus This is shown schemati...

Страница 12: ...uests commands address space 0 250 special addresses 253 0xFD 254 0xFE and 255 0xFF REQ_UD2 REQuest User Data type 2 request for consumption data transmitted over the M Bus by the master as a short fr...

Страница 13: ...eoretical values according to the data sheet approx 450 ms 440 mA without taking the internal impedance of the module into account approx 220 ms 530 mA approx 50 ms 3300 mA Reset behaviour of fuse at...

Страница 14: ...e transceivers such as MAX232 TX is therefore TXin data transmitted from the logic to the bus and RX is RXout data received from the bus to the logic Figure 5 Variant MBUS M13 S with galvanically isol...

Страница 15: ...Variant MBUS M13 G powering the external logic 3 3 VDC on its own max 50 mA Figure 8 Variant MBUS M13 M using only the connector X1 Frank Richter 6 December 2022 solvimus GmbH Version 1 09 Released P...

Страница 16: ...bus terminals test at 9600 bps test at 9600 bps Bus voltage blue at the transition of the TXD signal Bus voltage blue at the transition of the TXD signal purple on a load of 10 k and 1 F between the...

Страница 17: ...3 6 24 1 24 3 Fall time s 3 1 approx 45 approx 60 Rise time s 3 3 approx 25 approx 45 Delay at falling edge approx s 8 8 12 12 Delay at rising edge approx s 4 4 4 4 Table 9 Conditions and results of p...

Страница 18: ...manual 3 Accessory The usage of accessories not recommended is at your own risk It is imperative to mind Section 1 2 5 Page 18 18 UG_EN_MBUS M13 pdf Version 1 09 Released Frank Richter 6 December 2022...