Field Programmable Gate Array Registers
http://www.motorola.com/computer/literature
3-11
3
SEL0 (Bit 0), SEL1 (Bit 1) and SEL2 (Bit 2)
Use SEL0, SEL1 and SEL2 to select the watchdog timeout time. Writing
to these bits does not clear or reset the watchdog timer. Refer to
WD0 (Bit 3) and WD1 (Bit 4)
Use these bits to define the event that occurs on a watchdog timeout and to
disable the watchdog timer. Reading these bits returns the last value
written. Refer to
Table 3-8. Bit values for selecting watchdog timeout time
Period
SEL2
SEL1
SEL0
.46 seconds
0
0
0
.93 seconds
0
0
1
3.73seconds
0
1
0
14.91seconds
0
1
1
29.82 seconds
1
0
0
1.98 minutes
1
0
1
3.97 minutes
1
1
0
7.95 minutes
1
1
1
Table 3-9. Bit values defining watchdog timeout and disabling
WD1
WD0
Description
0
0
DISABLED - Resets watchdog
0
1
POLLED
1
0
FPGA IRQX
1
1
NMI followed by reset or soft reset (7.28ms delay
before SBC Reset)