12.- TECHNICAL SPECIFICATIONS 

 

Output wave form ....................................................................................................... 

Pure Sine Wave

Rated output voltage .......................................................................................... 230 (

120 optional

) V

AC

Rated output frequency ........................................................................................... 50 (

60 optional

) Hz

Output frequency variations ...................................................................................................... < 0,1 %
Output power variations ................................................................................................................< 5 %
Minimum Input Voltage .............................................................................................................. 5/6 V

nom

Maximum Input Voltage............................................................................................................. 4/3 V

nom

Efficiency .................................................................................................................................. 85-97 %
Efficiency with nominal load ....................................................................................................... > 85 %
Consumption (in detection) ...................................................................................................... < 70 mA
Harmonic Distortion .......................................................................................................................< 5 %
Environmental Protection Level ..................................................................................................... IP20
Relay Maximum Current .................................................................................................... 1 A resistive
 

Rated Power(VA) 

500 

750 

1000 

1250 

1500 

2200 

2500 

3000 

4200 

6000 

10000 

Rated Voltage (V) 

12/24 

12 

24 

12 

24 

12 

24/36/48 

12 

24/36/48 

24/36/48 

48 

Overload 3 ’’ (VA) 

750 

1100 

1500 

1800 

2200 

3300 

3700 

4500 

6300 

9000 

15000 

Overload 50 ’’ (VA) 

650 

1000 

1300 

1600 

1900 

2800 

3200 

3900 

5400 

7800 

13000 

Overload 6 ’ (VA) 

600 

900 

1200 

1500 

1800 

2600 

3000 

3600 

5000 

7200 

12000 

Length (mm) 

115 

315 

315 

315 

460 

460 

460 

535 

535 

535 

647 

Height (mm) 

230 

118 

118 

118 

157 

157 

157 

178 

178 

178 

210 

Width (mm) 

154 

192 

192 

192 

255 

255 

255 

285 

285 

285 

344 

Net Weight (kg) 

12 

20 

22 

22 

24 

36 

36 

68 

Relay (see Section 1) 

NO 

NO 

NO 

NO 

NO 

YES 

YES 

YES 

YES 

YES 

YES 

 

PROTECTIONS 

 

Against Reverse Polarity (using intelligent diode) 

 

Against High and Low Voltage  

 

Against Shortcircuit and Overload 

 

Against Over Temperature 

 

  36 V input or 120 V / 60 Hz output available upon request. Aluminum casing protected with epoxy paint.

 

DATA SUBJECT TO CHANGE WITHOUT NOTICE.

 

 
 

13.- SERVICE CODES 

 

These codes are an excerpt of those that can be used in the Service option in 

the menu to change the relay mode of operation:  

 
    65435470 ................................. Relay contacts close to start generator (default value) 
    65435471 ........................................................ Relay contacts open to start generator 
    6243547E ............................................. Relay contacts close when power is  too high 
    66435476 ............................... Relay contacts close when there is low battery voltage 
    61435478 ......................................... Relay contacts close when AC output is shut-off  
    6043547A ................................. Relay contacts close when there is over temperature 

Содержание SOLENER

Страница 1: ...NER Pure Sine Wave Inverter User Manual Version 1 14 June 2020 Soluciones Energéticas S A Avenida Real de Pinto 146 28021 Villaverde Alto Madrid Telephone 34 91 539 27 00 www solener com solener solener com ...

Страница 2: ...NGS 6 5 INVERTER PROTECTIONS 5 1 Overload Protection 7 5 2 Over Temperature Protection 7 5 3 Low and High Voltage Protection 7 6 INSTALLATION INSTRUCTIONS 6 1 Inverter Mounting 8 6 2 Wiring 8 7 START UP PROCEDURE 9 8 SHUT OFF PROCEDURE 9 9 PRECAUTIONS 9 10 MAINTENANCE 9 11 SAFETY INSTRUCTIONS 10 12 TECHNICAL SPECIFICATIONS 11 13 SERVICE CODES 11 14 WARRANTY 12 ...

Страница 3: ...oes not work Start up and shutdown is possible through any PROFESSIONAL SOLENER CONTROLLER using an optional control line In addition since the beginning of 2010 almost all versions feature a relay for generator start which is activated closing a potential free contact when the battery needs recharging This relay can be configured to perform other functions see some of these possible functions in ...

Страница 4: ... These element references will be used throughout this manual The small model has one multi color LED that brings together the functions of the seven LED present in rest of the models 1 Alphanumeric Screen 2 Acoustic Alarm 3 Load Disconnection Indicator 4 Shortcircuit Indicator 5 Battery Over Voltage Indicator 6 Battery Under Voltage Indicator 7 Over Temperature Indicator 8 Load Detection Indicato...

Страница 5: ...When the inverter DC voltage input drops to a value lower than the re start voltage setting the inverter will re start automatically Inverters produce heat when operating The amount of heat produced is almost proportional to the amount of power supplied by the inverter When the MOSFET reaches a certain programmed temperature 50 ºC by default the internal fan is activated stopping when the temperat...

Страница 6: ...attery input voltage and turns off when it drops to a safe operating voltage value Overload Red It flashes when a short circuit takes place It remains lit if it exceeds the overload preset time Load Disconnection Red It turns ON when the inverter has shut off AC output disconnected to protect the installation or the inverter itself The yellow or red LED that remains lit together with the Load Disc...

Страница 7: ...s the difference in form of heat particularly when the unit is operating close to its nominal power capacity When the inverter is subject to a heavy load for a prolonged period of time the overheating protection will be triggered in three stages first activating its internal fan then if the temperature keeps increasing it reduces the output voltage by 10 and if temperature continues rising it cuts...

Страница 8: ...e or with a red terminal to connect to the positive terminal of the battery A black or blue cable to connect to the negative terminal of the battery A three wire cable phase neutral and ground or an industrial connector for connection to the AC loads An optional two wire cable to connect to the remote control Battery cables have a terminal at the end which must be attached with bolts to the termin...

Страница 9: ...hat adjusted with the load detection potentiometer the inverter will start and the output voltage will increase rapidly until it reaches its nominal value If not load will turn ON and OFF once per second Verify that the RCD is working properly by pressing the test button on the front if it trips then it is working properly This cross check must be done occasionally as indicated by the manufacturer...

Страница 10: ...e battery correctly Overload or short circuit Load Disconnection and Shortcircuit if applicable LED alarms will turn on Turn OFF the inverter eliminate the cause of shortcircuit or overload and turn on the inverter again High Battery voltage Load Disconnection and High Battery Voltage LED alarms turn on Inverter automatically restarts beware when battery voltage drops to reconnection voltage Low B...

Страница 11: ...gth mm 115 315 315 315 460 460 460 535 535 535 647 Height mm 230 118 118 118 157 157 157 178 178 178 210 Width mm 154 192 192 192 255 255 255 285 285 285 344 Net Weight kg 4 9 9 12 20 22 22 24 36 36 68 Relay see Section 1 NO NO NO NO NO YES YES YES YES YES YES PROTECTIONS Against Reverse Polarity using intelligent diode Against High and Low Voltage Against Shortcircuit and Overload Against Over Te...

Страница 12: ... examine and test the product according to prevailing rates The warranty is solely limited to the repair materials and labor of the equipment in no case includes travel expenses freight or shipping costs or any damage caused by the use of or inability to use the equipment The use of our products in life support devices without the express written permission of our company President is specifically...

Отзывы: