![Soluciones Electronicas SOLENER Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/soluciones-electronicas/solener/solener_user-manual_1317018011.webp)
Inverter User Manual
Version 1.14, June 2020
11
12.- TECHNICAL SPECIFICATIONS
Output wave form .......................................................................................................
Pure Sine Wave
Rated output voltage .......................................................................................... 230 (
120 optional
) V
AC
Rated output frequency ........................................................................................... 50 (
60 optional
) Hz
Output frequency variations ...................................................................................................... < 0,1 %
Output power variations ................................................................................................................< 5 %
Minimum Input Voltage .............................................................................................................. 5/6 V
nom
Maximum Input Voltage............................................................................................................. 4/3 V
nom
Efficiency .................................................................................................................................. 85-97 %
Efficiency with nominal load ....................................................................................................... > 85 %
Consumption (in detection) ...................................................................................................... < 70 mA
Harmonic Distortion .......................................................................................................................< 5 %
Environmental Protection Level ..................................................................................................... IP20
Relay Maximum Current .................................................................................................... 1 A resistive
Rated Power(VA)
500
750
1000
1250
1500
2200
2500
3000
4200
6000
10000
Rated Voltage (V)
12/24
12
24
12
24
12
24/36/48
12
24/36/48
24/36/48
48
Overload 3 ’’ (VA)
750
1100
1500
1800
2200
3300
3700
4500
6300
9000
15000
Overload 50 ’’ (VA)
650
1000
1300
1600
1900
2800
3200
3900
5400
7800
13000
Overload 6 ’ (VA)
600
900
1200
1500
1800
2600
3000
3600
5000
7200
12000
Length (mm)
115
315
315
315
460
460
460
535
535
535
647
Height (mm)
230
118
118
118
157
157
157
178
178
178
210
Width (mm)
154
192
192
192
255
255
255
285
285
285
344
Net Weight (kg)
4
9
9
12
20
22
22
24
36
36
68
Relay (see Section 1)
NO
NO
NO
NO
NO
YES
YES
YES
YES
YES
YES
PROTECTIONS
•
Against Reverse Polarity (using intelligent diode)
•
Against High and Low Voltage
•
Against Shortcircuit and Overload
•
Against Over Temperature
36 V input or 120 V / 60 Hz output available upon request. Aluminum casing protected with epoxy paint.
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
13.- SERVICE CODES
These codes are an excerpt of those that can be used in the Service option in
the menu to change the relay mode of operation:
65435470 ................................. Relay contacts close to start generator (default value)
65435471 ........................................................ Relay contacts open to start generator
6243547E ............................................. Relay contacts close when power is too high
66435476 ............................... Relay contacts close when there is low battery voltage
61435478 ......................................... Relay contacts close when AC output is shut-off
6043547A ................................. Relay contacts close when there is over temperature