INSTALLATION & OPERATION:
4.1 Installation
Inspecting the packing carton for damage that may have occurred while in transit.
Immediately notify the carrier and place of purchase if any damage is found. Retain the
package for future use.
Plugging the power cord to a 3-wire grounding receptacle. If an extension cord must
be used between the UPS and the nearest wall outlet, use a 3-wire grounding type
rated for at least 20 Amps.
Connecting your equipment to the UPS. To ensure that your computer equipment will
be protected during a utility failure, it is important to make sure that the maximum
power need from the equipment is not over the rated capacity of the UPS. Red LED
will lighted up and alarm will beep if the load is over the rated value. Meantime, if the
overload is severe, the UPS will shut down immediately for protecting UPS itself.
4.2 Operation
4.2.1 After installation with normal city power, the UPS will charge the battery automatically,
and the status LED blinks green every 2 seconds. Please push the button about one
second on the front panel, then the UPS will give power to the outlets after a short-time
of self-test.
4.2.2 Pushing the button for 4 seconds, the UPS will turn off the power on the outlets. But, the
UPS will keep charging if city power is normal. To stop the charging, please pull out the
power cord to shut down the UPS completely.
4.2.3 During a blackout, push the button for entering idle mode (Ref. Indication Table),
then push again for one second, and the UPS will be turned on and enter into
backup mode. To turn off the power from UPS; please push the button for 4
seconds, then UPS status LED will blink orange every 2 seconds, wait for 5
seconds, and UPS will turn off the power automatically.
4.2.4 In idle mode, UPS will turn off the power automatically within 12 seconds during a
utility failure; while UPS will keep charging the batteries if the utility power is
normal. When utility power is normal, please pull out the power cord if you want
to turn off the UPS completely.
4.2.5 When “Green Power” function is enabled, the UPS will turn off the power within 30
seconds after blackout occurs with the power consumption lower than 25W.
4.3
Connecting the FAX machine:
When you are connecting a FAX machine or modem with the UPS, please also
connect the phone line through the UPS. The UPS may offer protection against
damaging power fluctuations and surges that travel through the phone line. The
UPS also offers a ring on function when the power is off. UPS power will be turned
on automatically when a ringing signal exists in the phone line, and the UPS will keep
power on until the FAX machine finishes receiving work, then the UPS will be
turned-off by the green power function. In a long-time blackout situation, you won’t
miss any FAX data by this function.