SOLO MINI_v2 User Manual
Part Number: SLM0322_4020
May 2022 - Revision V_1.0.1
Copyright © 2022, All right Reversed. SOLO motor controllers.
23
M1 Pin
Logic
M2 Pin
Logic
Motor Name Motor
code
Default
Switching
Frequency
Max Speed
with +5V at
“S/T” in
Closed-Loop
Speed /
Position
Controller
Sampling
Rate
High
High
Brushless
(ultra-fast /
Low
inductance)
3
80kHz
30000/ASRDC RPM
2kHz
High
Low
AC
Induction
2
20kHz
4000/ASRDC RPM
2kHz
Low
High
Brushless
(normal)
1
20kHz
8000/ASRDC RPM
2kHz
Low
Low
DC brushed
0
20kHz
Nominal Speed of the
motor
2kHz
-
ASRDC
Coefficient defines the resolution of the speed reference at the analogue
inputs, this coefficient is tunable using USB, UART or CANopen protocols and it has a
default value of 1, to know more about it, please refer to USB, UART or CANopen
manuals.
-
By selecting each motor type, the switching frequency of SOLO at the output will be
adapted to what has been mentioned in the table above. These are default values and
you can overwrite them using Digital commanding like by USB, UART or CANopen, by
setting them digitally to any value from 8kHz to 80kHz with incremental steps of 1kHz.
-
As a rule of thumb for Low inductance motors you should select higher values for
switching frequency at the output of SOLO, default 20kHz can be low for some types
of motors mainly with phase inductance lower than 200µH, and in case you are using
Brushless or PMSM motors, you can select the motor type number 3, which by default
has 80kHz of switching at the output, you can also change these values to your desired
value as mentioned above for any type of motor you select.