Troubleshooting PVA & SolSensor Operation:

 

Segmented or incomplete I-V trace: 

Just take a fresh trace.

 

Can occur on 

first measurement after I-V Unit is turned on or I-V curve has changed 
significantly. The PVA automatically optimizes its internal settings based on 
the results of the previous measurement.   

 

Searching for I-

V Unit” or “Searching for SolSensor” 

message: 

Equipment 

may be out of wireless range or may have turned itself off after extended 
inactivity (15 min). Improve line of sight, raise instruments above metal 
surfaces, or move equipment closer together.  

Wireless connection briefly drops out: 

May occur occasionally. The network 

should restore in 1-2 minutes. If not, re-connect your PC to the I-V Unit WiFi 
hotspot.    

“Disabled” message

:  

Click the status indicator for more information. Clear 

the underlying condition, (over-voltage, -current*, -temp, low battery) and 
reset I-V Unit or charge unit. 

Isc is much different than predicted: 

Check that SolSensor is mounted in the 

plane of the array, and that all 

Project

 values are correct (

Properties

 menu). 

 

 

Software updates:

  The latest PVA PC software and Data Analysis Tool are 

available online a

www.solmetric.com/downloads-pva.html

  

*Do not measure high-efficiency modules or strings in parallel 

 can cause 

over-current disable at start of I-V sweep.   

Solmetric Technical Support: 

Phone: 877-263-5026 ext 2, 

[email protected]

 

 
Copyright 2018 Solmetric Corp. All rights reserved.      Printed 6/17/2018  