Sollatek SVS04E Скачать руководство пользователя страница 2

Inlet

On/off switch

Fan

Cable entry

Fuse (case type A only)

Rear panel

All specifications are subject to change 

without prior notice.

Voltright SVS04E Manual March 2017 Rev 1.0

A/I: 10910271 

S/C: 74131708 

Specifications

 

Model  

SVS04-22

  Output Current  

4Amps 

 VA@230V 

920V

 VA@240V 

960V

  Weight  

7.2kg 

  Case type   

Plastic 

  AVS function  

YES

  Spike protection  

YES

  Dimension unpacked(mm)  

162 x 132 x 275

Input/output range 

  Input range 

 95 - 290V

  Output 

182 - 245V

  Frequency range 

45Hz to 75Hz

 General 

  Derating factor  

10% to 15% per 10°C above 40°C

  Synchronization 

Output synchronized to input

  Permissible overload 

1000% for 100ms,  

     

150% for 4 minutes,  

     

110% for 15 minutes

  Load types  

Suitable for fridges, freezers, coolers and vending machines rated up to 4A 

  Technology 

Transformer tap switching using relay based

  Efficiency  

>97%  (at 100%  linear load)

  Control 

Microcontroller based control system provides self checks, system integrity monitoring and  

     

diagnostic indicators

  Control protection 

Internal surge arrestors and filters in control circuit protect against disturbances. Filtering  

     

algorithms and fault tolerant software protect against disturbances and false measurements

  Ambient temperature range  

0 to +55ºC             

  Relative humidity  

<95%, non condensing

  Acoustic noise 

< 45 dB (A)

  Expected service life  

> 10 years

  Standards 

Manufactured to comply with :- ISO9001:2000, CE, EN 50081-1:1992, EN 50082-1:1998,  

     

EN 55022:1998, EN 61000-4-2:1995/1998, EN 61000-4-3:1996, EN 61000-4-4:1995,  

     

EN 61000-4-5:1995, EN 61000-4-6:1996, EN 61000-4-11:1994, DD ENV 50204, BS EN 61558-1,  

     

EN 60065,  EN 60555

  Correction speed 

750 Volts per sec

  Response   

Within 0.1 second 

  Efficiency   

88% at 25% load, 94% at 50% load, 96% at 75% load, 97% at 100% load

  Power factors  

Unaffected by  load power factor

  AVS™ function 

Automatic voltage switcher: output is switched off to protect device against over and under  

    

voltage

  TimeSave™ function 

Reduced startup delay if unit was off for more than the standard delay period to 10 seconds

Sollatek (UK) Ltd.  

Sollatek House, Waterside Drive, Langley, Slough SL3 6EZ UK

ISO9001: 2008 accredited company

All weights and dimensions are approximate. Specifications are subject to change 
without prior notice. ©Sollatek (UK) Limited 2012. All Rights Reserved. SOLLATEK 
and the SOLLATEK device are the trade marks of the Sollatek group of companies.

SOLLATEK UK LTD.

Tel: +44 (1753) 214 500 

[email protected]   
www.sollatek.com

For more information on Sollatek's 
voltage protection range refer to the 
VP Catalogue.  
or visit www.sollatek.com

www.sollatek.com

the power to protect

the power to protect

Guarantee

Sollatek (UK) Ltd guarantee that if within 2 years 

of purchase this appliance fails due to faulty 

workmanship or materials we will repair or 

replace it free of charge provided that:

• The appliance has been correctly installed 

and used within the electrical range as 

specified on the appliance nameplate.

• The appliance has been used in accordance 

with the operating instructions.

•There has been no attempt to open the unit 

for any reason whatsoever.

• The unit is returned to Sollatek or Sollatek 

agent in good condition.

• Sollatek shall not be liable under the terms 

of this guarantee for any material fault or 

damage as a result of failure of this appliance.

• This guarantee does not affect your statutory 

or Common Law rights.

Warranty & Returns

Should your SVS unit need repair, the quickest and simplest way is 

to return it to your dealer or to a Sollatek Service Centre or direct to 

the nearest Sollatek office.

IMPORTANT : Before returning a unit to a Sollatek Service Centre, 

contact the returns department to obtain a returns number. You 

will be asked for the following information which you should have 

ready;

Your name, address, telephone, fax (if available), email (If 

available)

Date purchased, where purchased

Serial number, model number 

Local voltage and type of load.

Description of fault

Once you have the returns number, ensure that the unit is securely 

packed enclosing a  short note with details as above and mark the 

unit clearly with the returns number. Remember also to add your 

name and address. 

Complying with the above will ensure that your unit will be treated 

promptly and efficiently. Without a returns number it will not be 

possible to trace a unit or check progress of repair of the unit.

SVS04E instruction sheet V2.indd   2

29/03/2017   12:25

Отзывы: