9
8
FRIDGEGUARD
The Fridgeguard is an under-voltage
protection device rated at 5 Amps.
The Fridgeguard will disconnect if
the mains go below the lower limit
and re-connect automatically after
the supply returning and remaining
above the lower limit for the duration
of the wait time.
PLEASE READ CAREFULLY.
1. Make sure that your load does not exceed the rating of the
Fridgeguard which is 5 AMPS. If this is exceeded, the
Fridgeguard may be damaged, and the warranty will be void.
2. Plug the Fridgeguard into the mains and plug your appliance
into the Fridgeguard.
3. Do not connect more than one appliance to the Fridgeguard.
4. On first switching on, the yellow LED will indicate and there
will be no output while the Fridgeguard monitors the mains. If
the mains level is acceptable, the Yellow LED is lit indicating
that the Fridgeguard is in wait mode. At the end of the wait
time and if the supply is above the lower limit the green LED
goes on and the load is connected.
5. It is recommended that the Fridgeguard is kept switched on,
and the appliance switched on and off as required, to prevent
activating the time delay every time the appliance is switched on.
6. If the red LED shows, the voltage is too low. When the
voltage is acceptable, the Fridgeguard will go to yellow.
SPECIFICATIONS
CONNECTION DIAGRAM
Please note: Some of these values (i.e. HVD, LVD and wait time) may be
different to adapt to local market conditions.
Fridge/freezer/cooler
Nominal Voltage
230V (or 110V)
Current Rating
5Amps
Frequency
50/60Hz
Mains Spike Response Time <10ns
Mains Spike Discharge Amps 6.5kA
Spike Protection
160J
Wait Time
90 seconds
Ideal For
Fridges, freezers and coolers
Socket availability
UK13, Schuko, 5A Indian
Weight 250gm
Dims 180x90x95mm