background image

9

8

FRIDGEGUARD 

The Fridgeguard is an under-voltage
protection device rated at 5 Amps.
The Fridgeguard will disconnect if
the mains go below the lower limit
and re-connect automatically after
the supply returning and remaining
above the lower limit for the duration
of the wait time. 

PLEASE READ CAREFULLY.

1. Make sure that your load does not exceed the rating of the
Fridgeguard which is 5 AMPS. If this is exceeded, the
Fridgeguard may be damaged, and the warranty will be void.

2. Plug the Fridgeguard into the mains and plug your appliance
into the Fridgeguard.

3. Do not connect more than one appliance to the Fridgeguard.

4. On first switching on, the yellow LED will indicate and there
will be no output while the Fridgeguard monitors the mains. If
the mains level is acceptable, the Yellow LED is lit indicating
that the Fridgeguard is in wait mode. At the end of the wait
time and if the supply is above the lower limit the green LED
goes on and the load is connected.

5. It is recommended that the Fridgeguard is kept switched on,
and the appliance switched on and off as required, to prevent
activating the time delay every time the appliance is switched on.

6. If the red LED shows, the voltage is too low. When the
voltage is acceptable, the Fridgeguard will go to yellow.

SPECIFICATIONS

CONNECTION DIAGRAM

Please note: Some of these values (i.e. HVD, LVD and wait time) may be
different to adapt to local market conditions.

Fridge/freezer/cooler

Nominal Voltage  

230V (or 110V)

Current Rating  

5Amps

Frequency  

50/60Hz

Mains Spike Response Time    <10ns

Mains Spike Discharge Amps   6.5kA 

Spike Protection   

160J

Wait Time  

90 seconds

Ideal For 

Fridges, freezers and coolers

Socket availability 

UK13, Schuko, 5A Indian 

Weight 250gm

Dims 180x90x95mm

Содержание Commsguard

Страница 1: ...OLLATEK GUARD RANGE Instruction manual Important This manual contains important safety instructions Keep this manual handy for reference FRIDGEGUARD VOLTGUARD COMMSGUARD FAXGUARD HIVOLTGUARD SPIKEGUAR...

Страница 2: ...ting An unpredictable power supply can lead to worrying problems events such as surges spikes brownouts and utility failures If any of these should occur there s a strong chance you will suffer from l...

Страница 3: ...phase Automatic Voltage Switcher AVS3P 03 unlimited 3 phase In line Surge protector ISP 10 IEC Surge plug 13 13 Amp plug Surge strip 13 Plug socket SpikeGuard 13 Plug socket PureAC 3 to 13 Plug socket...

Страница 4: ...the equipment to malfunction or not work at all Repeated episodes are certain to cause damage Motors and compressors and therefore fridges freezers coolers air conditioners and pumps are especially at...

Страница 5: ...is acceptable the Yellow LED is lit indicating that the Fridgeguard is in wait mode At the end of the wait time and if the supply is above the lower limit the green LED goes on and the load is connec...

Страница 6: ...nto the mains and plug your appliance into the Voltguard 3 Do not connect more than one appliance to the Voltguard 4 On first switching on the red LED will indicate and there will be no output while t...

Страница 7: ...not or you are unsure then contact your electrician or a Sollatek retailer 4 Plug your fax machine s mains plug into it 5 From the fax machine end unplug the telephone cable and plug it into the LINE...

Страница 8: ...f the Faxguard indicate the state of the mains output from the Faxguard If the incoming supply voltage is too high the disconnect function will operate and the OFF LED will be lit When the supply beco...

Страница 9: ...mains If the mains level is acceptable the Yellow LED is lit indicating that the Fridgeguard is in wait mode At the end of the wait time and if the supply is below the upper limit the green LED goes o...

Страница 10: ...AMPS If this is exceeded the Spikeguard may be damaged and the warranty will be void 2 Plug the Spikeguard into the mains and plug your appliance into the Spikeguard 3 More than one appliance can be...

Страница 11: ...ks of the Sollatek group of companies SOLLATEK UK LTD UNIT 10 POYLE 14 INDUSTRIAL ESTATE NEWLANDS DRIVE POYLE SLOUGH SL3 0DX UNITED KINGDOM Tel International 44 1753 688300 National 01753 688300 Fax I...

Отзывы: