Exemption from Liability 

7.2.1

 

 English version 

In no event shall Sollae Systems Co., Ltd. and its distributors be liable for any 

damages  whatsoever  (including,  without  limitation,  damages  for  loss  of  profit, 

operating  cost  for  commercial  interruption,  loss  of  information,  or  any  other 

financial loss) from the use or inability to use the SIG-5450 even if Sollae Systems 

Co., Ltd. or its distributors have been informed of such damages. 

 

The SIG-5450 is not designed and not authorized for use in military applications, 

in  nuclear  applications,  in  airport  applications  or  for  use  in  applications 

involving explosives,  or  in  medical  applications, or for  use in  security alarm,  or 

for  use  in  a  fire  alarm,  or  in  applications  involving  elevators,  or  in  embedded 

applications  in  vehicles  such  as  but  not  limited  to  cars,  planes,  trucks,  boats, 

aircraft, helicopters, etc. 

 

In the same way, the SIG-5450 is not designed, or intended, or authorized to test, 

develop,  or  be  built  into  applications  where  failure  could  create  a  dangerous 

situation that may result in financial losses, damage to property, personal injury, 

or  the  death  of  people  or  animals.  If  you  use  the  SIG-5450  voluntarily  or 

involuntarily  for  such  unauthorized  applications,  you  agree  to  subtract  Sollae 

Systems  Co.,  Ltd.  and  its  distributors  from  all  liability  for  any  claim  for 

compensation.  

 

Sollae Systems Co., Ltd. and its distributors entire liability and your exclusive 

remedy shall be Sollae Systems Co., Ltd. and its distributors option for the return 

of the price paid for, or repair, or replacement of the SIG-5450.  

 

Sollae  Systems  Co.,  Ltd.  and  its  distributors  disclaim  all  other  warranties, 

either  expressed  or  implied,  including,  but  not  limited  to,  the  implied  warranties 

of  merchantability  and  fitness  for  a  particular  purpose,  with  respect  to  the  SIG-

5450 including accompanying written material, hardware and firmware. 

 

 

Содержание SIG-5450

Страница 1: ...Sollae Systems https www ezTCP com 2 Port Digital Output I O Gateway SIG 5450 User Manual Version 1 1...

Страница 2: ...cal and electronic equipment By ensuring this product is disposed of correctly you will help prevent potential negative consequences to the environment and human health which could otherwise be caused...

Страница 3: ...0 2 3 Searching Devices 10 2 4 Logging in 10 3 Settings 11 3 1 Network 11 3 1 1 Obtain an IP address automatically 11 3 1 2 Use a Static IP address 12 3 2 General 13 3 2 1 Comment 13 3 2 2 TCP 13 3 2...

Страница 4: ...2 Digital Output Pulse Control Register 25 5 1 3 Activating DO Status Change Notification Register 25 5 2 Read Only 26 5 2 1 Device Information Register 26 6 Technical Support and Warranty 27 6 1 Tech...

Страница 5: ...te user devices via Modbus TCP 1 2 Features 2 digital output ports Relay Both NO and NC output Support pulse mode on digital output ports Support Modbus TCP Support multiple TCP connection Max 4 chann...

Страница 6: ...4 IPv6 Dual Stack TCP UDP ICMP DHCP mDNS Modbus TCP SSL TLS Indicators LED PWR STS MTX MRX Do0 Do1 Management spFinder Configuration and Monitoring Tool Security Password Dimension Size 94mm x 57mm x...

Страница 7: ...SIG 5450 User Manual Ver 1 1 6 https www ezTCP com 1 4 Interface Figure 1 1 Interface 1 4 1 Power SIG 5450 requires DC5V power supply whose specification is as follows Figure 1 2 Power...

Страница 8: ...2 Max Allowed Current at DC 30V Normal Open 5A Normal Close 1A Table 1 2 Port Specification The port specifications are for resistive loads It is recommended to design about 10 20 of the maximum allow...

Страница 9: ...SIG 5450 User Manual Ver 1 1 8 https www ezTCP com 1 4 4 LED SIG 5450 provides 8 LEDs Figure 1 5 4 LED...

Страница 10: ...t is running RUN When a network is not connected LINK When a network is connected LINK When a TCP connection is NOT established MTX MRX When sending data to the TCP MTX When receiving data from the TC...

Страница 11: ...LAN cable or a USB cable In the case of using a LAN cable note that your PC and the product should be on the same local area network 2 3 Searching Devices Run spFinder on your PC and press the search...

Страница 12: ...IP address automatically This product can automatically obtain an IP address by DHCP A DHCP server is required to use this Figure 3 1 Obtain an IP address automatically Select the Obtain an IP address...

Страница 13: ...com 3 1 2 Use a Static IP address You can set a static IP address to this product Figure 3 2 Use a static IP address Select the Use static IP address Set the Local IP address Subnet mask Gateway IP a...

Страница 14: ...to It is valid only when the Connection Mode is set to TCP Client Port This item is to set the port number for the TCP connection It can be set between 0 and 65535 The default is 502 Multiple Connect...

Страница 15: ...his item is to set the output delay time When the product receives an output control frame from the master it delays the output by the time set in this item The setting unit is milliseconds The range...

Страница 16: ...ick the Save button 3 3 2 Certificate This is NOT available for this product 3 3 3 spFinder These items are related to spFinder use Local search If this item is not checked you will not be able to sea...

Страница 17: ...er 1 1 16 https www ezTCP com Remote access If this item is checked the product can be connected from the remote network For security this item is unchecked by default 3 3 4 Client ID This is NOT avai...

Страница 18: ...ose the window or time out While the connection is maintained other hosts cannot access the product using the spFinder 4 1 1 Product Information Product Information Window This area shows some major i...

Страница 19: ...P and port of the connected host will be shown CONNECTING Connecting DISCONNECTING Disconnecting Table 4 2 TCP STATE MODBUS STATISTICS Item Description RX0 3 Statistics of incoming data from TCP TX0 3...

Страница 20: ...ATISTICS 4 1 3 Timeout This is the timeout display function that appears in the upper right of the status window When this time reaches zero the connection between spFinder and the product is lost The...

Страница 21: ...ou can upgrade it to the latest version Firmware can be upgraded online or manually via spFinder 4 2 1 Online Upgrade If you can access to the Internet by your PC the Firmware can be upgraded online F...

Страница 22: ...4 4 Manual Upgrade Download a Firmware file to your PC Search and connect to your product by spFinder Click Advanced Firmware Change menu Select to Manual upgrade on the Firmware Upgrade window Click...

Страница 23: ...le the connection is maintained other hosts cannot access the product using the spFinder Figure 4 5 Console 4 3 1 Output Tab This tab displays console messages Clear output Pressing this button clears...

Страница 24: ...nection between spFinder and the product is lost The initial value is 30 minutes If you move the mouse pointer in the internal area of the console window the timer is reset to the initial value again...

Страница 25: ...the password Follow the procedure below by checking the status of RUN LED 1 Press and immediately release the function button 2 Press the function button and keep the state more than 5 seconds 3 Once...

Страница 26: ...ister is allowed to write only when the port s Pulse Mode is set to Enable Division Address Bit Count Type Function Code HMI Addressing Example Port 0 80 1 Boolean 01 05 or 15 00081 Port 1 81 1 Boolea...

Страница 27: ...C Address 442 9 ASCII 03 40443 IP Address 451 8 ASCII 03 40452 Table 5 4 Device Information Register Vendor Name This is the Vendor Name Product Code This is the product code Version Major Minor Revis...

Страница 28: ...com en support qna php 6 2 Warranty 6 2 1 Free Repair Services For product failures occurring within 2 years after purchase Sollae Systems provides free repair services or exchange the product However...

Страница 29: ...applications provided by Sollae Systems for purposes other than those for which they were designed is prohibited Do not use the product in an extremely cold or hot place or in a place where vibration...

Страница 30: ...ars planes trucks boats aircraft helicopters etc In the same way the SIG 5450 is not designed or intended or authorized to test develop or be built into applications where failure could create a dange...

Страница 31: ...r utiliser le bo tier SIG 5450 m me si Sollae Systems Co Ltd ou un de ses distributeurs a t inform de la possibilit de tels dommages Le bo tier SIG 5450 est exclusivement pr vu pour un usage en int ri...

Страница 32: ...llae Systems Co Ltd et de ses distributeurs ne puissent tre mise en cause ni que le bo tier SIG 5450 puisse tre chang au titre de la garantie Rappel sur l vacuation des quipements lectroniques usag s...

Страница 33: ...or 2020 09 08 1 0 1 Created Roy Lee 2021 09 01 1 1 1 Improve the 1 2 Features 2 Apply changes of general settings 3 Apply changes of status function 4 Add a register Activating DO Change Notification...

Отзывы: