SIG-5441 User Manual Ver. 1.1
- 17 -
3.2.2
Digital Input
⚫
Valid Time (Unit: ms)
This item is to set the valid time of input signal. In order for the input signal to be
judged as a valid signal, it must last longer than the time set in this item. The setting
unit is milliseconds; The range is 100 to 30000. The default value is 100.
⚫
Counter Type
This item is to set the counter type of each port. You can choose one among three
options: Rise (rising edge), Fall (falling edge) and Both (rising edge or falling edge).
The default value is Rise.
⚫
Counter Direction
This item is to set the counter direction: Up (counting up) or Down (counting
down). The default value is Up
⚫
Default Count Value
The value that counter will start after the device booting up.
Valid Time, Counter Type, Counter Direction, and Default Count Value can also be
set via Sollae Cloud after the device is registered under an account.
User Interface and other features configurations can only be set via Sollae Cloud.