background image

SMG-5400 User Manual Ver. 1.4 

 

- 23 - 

https://www.ezTCP.com

 

 

 

Remote access 

If this item is checked, the product can be connected from the remote network. 

For security, this item is unchecked by default. 

4.4.4

 

Client ID 

This is NOT available for this product. 

 

 

Содержание SMG-5400

Страница 1: ...Sollae Systems https www ezTCP com Wireless LAN Modbus Gateway SMG 5400 User Manual Version 1 4...

Страница 2: ...ensuring this product is disposed of correctly you will help prevent potential negative consequences to the environment and human health which could otherwise be caused by inappropriate disposal of th...

Страница 3: ...ation 12 3 1 Installing the Setting Tool 12 3 2 Connecting a Product 12 3 3 Searching Devices 12 3 4 Logging in 12 4 Settings 13 4 1 Wireless LAN 13 4 1 1 Infrastructure 13 4 1 2 Soft AP 14 4 1 3 Adva...

Страница 4: ...anual Upragde 28 5 3 Console 29 5 3 1 Output Tab 29 5 3 2 FW Log Tab 30 5 3 3 Timeout 30 5 4 Export Import Setting Values 30 5 5 Factory Reset 31 6 Technical Support and Warranty 32 6 1 Technical Supp...

Страница 5: ...ed when the timer related requirements of the RTU mode cannot be met Coding System 8 bit binary Hexadecimal ASCII characters Bits per Byte 1 start bit 8 data bits LSB sent first 1 parity bit or no par...

Страница 6: ...cannot directly communicate with devices that use serial line Modbus protocols Because not only the physical interfaces are different but also the protocols are not compatible If you want to implemen...

Страница 7: ...S422 or RS485 Support multiple TCP connection Max 4 channels Self developed TCP IP stack RP SMA connector for an external antenna 2 3 Specification Serial Physical Interface Serial Interface RS232 RXD...

Страница 8: ...5mm x 57mm x 23mm excluding antenna Weight about 65g excluding antenna Operating Environment Input Voltage DC5V 0 5V Current Consumption typically 210mA Operating Temperature 20 60 Storage Temperatur...

Страница 9: ...SMG 5400 User Manual Ver 1 4 8 https www ezTCP com 2 4 Interface Figure 2 1 Interface 2 4 1 Power SMG 5400 requires DC5V power supply whose specification is as follows Figure 2 2 Power...

Страница 10: ...N ODD MARK or SPACE Data bit 8 or 7 7 bit is only available on using Parity Stop bit 1 or 2 Table 2 2 Port Specification RS232 Signal Lines Number Name Description Level I O Wiring 1 DCD Data Carrier...

Страница 11: ...S485 In Out Required Table 2 4 RS485 Signal Lines RS422 Signal Lines Number Name Description Level I O Wiring 1 TX Transmit Data RS422 Out Required 3 RX Receive Data RS422 In Required 4 RX Receive Dat...

Страница 12: ...LINK When a network is connected and an IP address is NOT assigned LINK When a network is connected and an IP address is assigned LINK When a TCP connection is NOT established MTX MRX When sending dat...

Страница 13: ...ducts Monitoring status of products 3 2 Connecting a Product Connect a product with your PC via a USB cable 3 3 Searching Devices Run spFinder on your PC and press the Open button with selecting the C...

Страница 14: ...ess network includes an Access Point AP in the infrastructure mode Related information of the AP SSID shared key and etc is required to be set on your product to connect the product to the AP Figure 4...

Страница 15: ...to an IP address among 192 168 0 3 to 192 168 255 254 Each client is not allowed to communicate with another client but communicates with SMG 5400 Use this mode when there is no AP on the network or...

Страница 16: ...802 11b and 802 11b g mode Short Preamble Under good condition of WLAN environment you can expect a slight improvement by enabling this option Otherwise you had batter to disable this option Short Slo...

Страница 17: ...ddress automatically This product can automatically obtain an IP address by DHCP A DHCP server is required to use this Figure 4 5 Obtain an IP address automatically Select the Obtain an IP address aut...

Страница 18: ...com 4 2 2 Use a static IP address You can set a static IP address to this product Figure 4 6 Use a static IP address Select the Use static IP address Set the Local IP address Subnet mask Gateway IP a...

Страница 19: ...l line Modbus data You can select Modbus RTU mode or Modbus ASCII mode and the default is Modbus RTU 4 3 3 Baudrate unit bps This setting selects a baud rate of serial port You can select one from the...

Страница 20: ...direction of Modbus query You can select TCP to Serial or Serial to TCP If you select TCP to Serial the product operates as a TCP server On the other hand if you select Serial to TCP the product opera...

Страница 21: ...e network In addition this value is used as unit ID when passing query frame of master received from the serial line to slave On the other hand if this value is 0 the product forwards all valid query...

Страница 22: ...ne TCP session TCP0 can be used If this item is set to Enable the rest of TCP sessions TCP1 to 3 are activated It means you can use 4 sessions at the same time TCP Timeout Unit sec This setting define...

Страница 23: ...lick the Save button 4 4 2 Certificate This is NOT available for this product 4 4 3 spFinder These items are related to spFinder use Local search If this item is not checked you will not be able to se...

Страница 24: ...er 1 4 23 https www ezTCP com Remote access If this item is checked the product can be connected from the remote network For security this item is unchecked by default 4 4 4 Client ID This is NOT avai...

Страница 25: ...ting the product with spFinder press the Status button to display this window When you open this window the spFinder connects to the product and keeps the connection until you close the window or time...

Страница 26: ...me since it boots up day hour min sec IPv4 Assigned IPv4 address Subnet Assigned subnet mask Gateway Assigned gateway IP address DNS Assigned DNS IP address SSID Configured SSID Table 5 1 Product Info...

Страница 27: ...count from invalid data of the master Reply Transmitted frame count to the master Table 5 3 MODBUS STATISTICS DEVICE STATISTICS Item Description TCP0 3 The byte count of the TCP data TX RX DROP EIO0 T...

Страница 28: ...a spFinder 5 2 1 Automatic Onine Upgrade The automatic online upgrade is available when you connect your device via USB tab on spFinder and your PC has the Internet connectivity The automatic online u...

Страница 29: ...5 4 Manual Upgrade Download a Firmware file to your PC Search and connect to your product by spFinder Click Advanced Firmware Change menu Select to Manual upgrade on the Firmware Upgrade window Click...

Страница 30: ...until you close the window or time out While the connection is maintained other hosts cannot access the product using the spFinder Figure 5 5 Console 5 3 1 Output Tab This tab displays console messag...

Страница 31: ...f the console window When this time reaches zero the connection between spFinder and the product is lost The initial value is 30 minutes If you move the mouse pointer in the internal area of the conso...

Страница 32: ...the password Follow the procedure below by checking the status of RUN LED 1 Press and immediately release the function button 2 Press the function button and keep the state more than 5 seconds 3 Once...

Страница 33: ...com en support qna php 6 2 Warranty 6 2 1 Free Repair Services For product failures occurring within 2 years after purchase Sollae Systems provides free repair services or exchange the product However...

Страница 34: ...applications provided by Sollae Systems for purposes other than those for which they were designed is prohibited Do not use the product in an extremely cold or hot place or in a place where vibration...

Страница 35: ...ars planes trucks boats aircraft helicopters etc In the same way the SMG 5400 is not designed or intended or authorized to test develop or be built into applications where failure could create a dange...

Страница 36: ...r utiliser le bo tier SMG 5400 m me si Sollae Systems Co Ltd ou un de ses distributeurs a t inform de la possibilit de tels dommages Le bo tier SMG 5400 est exclusivement pr vu pour un usage en int ri...

Страница 37: ...llae Systems Co Ltd et de ses distributeurs ne puissent tre mise en cause ni que le bo tier SMG 5400 puisse tre chang au titre de la garantie Rappel sur l vacuation des quipements lectroniques usag s...

Страница 38: ...2 Apply changes of spFinder UI 3 Apply changes of parameters Slave Address Unit ID Flow Control 4 Improve some expressions Roy Lee 2020 09 03 1 3 1 Apply changes of F W p4 2 Apply changes of spFinder...

Отзывы: