Max. DC input voltage (Volts)
MPPT voltage range (Volts)
Max. input current (Amps)
MPPT number/Max input strings number
Rated grid voltage (Volts)
Rated output current (Amps)
Power Factor (at rated output power)
Operating frequency range (Hertz)
Max.efficiency
EU efficiency
Model
Dimensions
Weight
333W*573H*249D (mm)
600
10+10+10
15.6+15.6+15.6
3/3
220/230
50/60
98.1%
97.6%
18kg
Rated output power (Watts)
Max. output power (Watts)
Max. apparent output power (VA)
330
6000
6600
6600
27.3/26.1
Solis-1P6K3-4G
THDi (at rated output power)
<1.5%
100...500
Startup voltage (Volts)
120
Max short circuit input current (Amps)
Max. DC input voltage (Volts)
MPPT voltage range (Volts)
Max. input current (Amps)
MPPT number/Max input strings number
Rated grid voltage (Volts)
Rated output current (Amps)
Power Factor (at rated output power)
Operating frequency range (Hertz)
Max.efficiency
EU efficiency
Model
Dimensions
Weight
333W*573H*249D (mm)
600
10+10+10
15.6+15.6+15.6
3/3
220/230
50/60
98.1%
97.6%
18kg
Rated output power (Watts)
Max. output power (Watts)
Max. apparent output power (VA)
330
7000
7700
7700
31.8/30.4
Solis-1P7K-4G
THDi (at rated output power)
<1.5%
100...500
Startup voltage (Volts)
120
Max short circuit input current (Amps)
Rated DC voltage (Volts)
Rated grid frequency (Hertz)
Rated DC voltage (Volts)
Rated grid frequency (Hertz)
.34.
.35.
>
0.99 (0.8 leading - 0.8 lagging)[1]
45...55 or 55...65
>
0.99 (0.8 leading - 0.8 lagging)
45...55 or 55...65
Operating ambient temperature range
Ingress protection
Noise emission (typical)
Cooling concept
Max.operation altitude
Grid connection standard
IP65
<30 dBA
Natural convection
4000m
Display
Communication connections
Warranty Terms
LCD, 2×20 Z.
5 Years (Extend to 20 Years)
VDE-AR-N 4105, VDE V 0124, VDE V 0126-1-1,
UTE C15-712-1, NRS 097-1-2, G98, G99,
EN 50549-1/-2, RD 1699, UNE 206006,
UNE 206007-1, IEC 61727
Self consumption (night)
<
1 W(Night)
-
25
℃
...
+60
℃
Safety/EMC standard
IEC 62109-1/-2, IEC 62116 ,EN 61000-6-1/-2/-3/-4
DC connection
AC connection
MC4 connector
RS485, Optional: Wi-Fi, GPRS
Relative humidity
0~100%
Quick connection plug
Topology
Transformerless
Operating ambient temperature range
Ingress protection
Noise emission (typical)
Cooling concept
Max.operation altitude
Grid connection standard
IP65
<30 dBA
Natural convection
4000m
Display
Communication connections
Warranty Terms
LCD, 2×20 Z.
5 Years (Extend to 20 Years)
VDE-AR-N 4105, VDE V 0124, VDE V 0126-1-1,
UTE C15-712-1, NRS 097-1-2, G98, G99,
EN 50549-1/-2, RD 1699, UNE 206006,
UNE 206007-1, IEC 61727
Self consumption (night)
<
1 W(Night)
-
25
℃
...
+60
℃
Safety/EMC standard
IEC 62109-1/-2, IEC 62116 ,EN 61000-6-1/-2/-3/-4
DC connection
AC connection
MC4 connector
RS485, Optional: Wi-Fi, GPRS
Relative humidity
0~100%
Quick connection plug
Topology
Transformerless