15

14

Piping

•  Select either standard or relay system piping per the examples below.
•  When only one system is used with the control board (HKA and EKE models), place a 

blind stopper in the unused system.

•  In the control board (HKA and EKE models), the Knocker can be connected to line A or 

line B, but note that the pressure accumulation and percussion operations are reversed 
on one system.

1. EXAMPLE IN STANDARD PIPING: A/B/C

    A. When using a three-way solenoid valve:

    B. When using the HKA and EKE model exclusive control board:

    C. When using the air operation controller KNR-CONTROL AOC model:

5/16 OD

KNR-CONTROL AOC

OFF

ON

When using the air operation controller KNR-CONTROL AOC

Air Knocker

Exhaust

Filter Regulator

Compressor

Control panel

Power Source

5/16 OD

A line

B line

Exhaust

When using the HKA, EKE exclusive control panel

Hopper

Air Knocker

Filter Regulator

Compressor

2. TUBE LENGTH IN STANDARD PIPING

•  Make air lines as short as possible to maximize the impact force. 
•  The maximum length of a piping tube changes with model, air pressure, 

and control unit, and may decrease Knocker effectiveness by 10 to 20%.

•  When adding another pipe, the length of the tube from the branch point to each Knocker 

should be equal. 

•  Avoid extreme bending and adding extra lines. It may affect operation  and impact force 

especially in units furthest from the air supply. 

•  It is recommended to set the minimum tube pressure at 44 psi to maintain stable 

performance. Impact force can be maintained by increasing air pressure. 

•  When arranging the piping between the Knocker and the control devices, use nylon or 

urethane tube which has a OD of 5/16 in.

    A. When using the solenoid valve:

    B. When using the HKA and EKE model 

        exclusive control board (per system):

    C. Maximum Tube Length (ft) between KNR-CONTROL AOC and Knocker:

Model (KNR-)

Tube Length (ft)

15-SS / 15

6.5

20 / 20-SS / 20

6.5

30 / 30-SS / 30-DI

6.5

40 / 40-SS / 40-DI

9.75

60 / 60-SS / 60-DI

26.25

80 / 80-DI

32.75

100 / 100-DI

80 / 80-DI

100 / 100-DI

40 / 40-SS / 40-DI

60 / 60-SS / 60-DI

30 / 30-SS / 30-DI

20 / 20-SS

15-SS

66

49

32

16

0

Pressure (PSI)

Tube length (feet)

When using solenoid valve

44

58

73

87

102

Pressure (PSI)

80 / 80-DI

100 / 100-DI

40 / 40-SS / 40-DI

60 / 60-SS / 60-DI

30 / 30-SS / 30-DI

20 / 20-SS
15-SS

262

197

131

66

0

44

58

73

87

102

Tube length (feet)

When using the HKA, EKE model exclusive control panel  (per system)

When using with three-way solenoid valve

Compressor

Filter Regulator

Timer1

Complex timer or Switch

Timer2

Air Knocker

Hopper

OUT

IN

EXH

Содержание Air Knocker Series

Страница 1: ...KNR 30 DI KNR 40 DI KNR 60 DI KNR 80 DI KNR 100 DI KNR 20 KNR 20 SS KNR 30 KNR 40 KNR 30 SS KNR 40 SS KNR 60 KNR 80 KNR 60 SS KNR 100 Since 1985 Instruction Manual AIR KNOCKER SERIES KNR 15 SS...

Страница 2: ...equipped with a breaker for preventing electric shock CAUTION TO PREVENT INJURY OR DAMAGES When removing the piping tube please be sure to close the air supply from the control equipment and to releas...

Страница 3: ...e or operation problems Only start air lines after checking that there is no foreign substance chips or slag on the piping materials Flush with the air pressure of 44 psi or more to clean any debris o...

Страница 4: ...When Discharge Exhaust Outside When Use Exhaust Filter Exhaust filter Tube connector Extension tube Push one elbow Cylinder Mushroom valve Piston Piston ring Spring Exhaust port Impact plate Inner bas...

Страница 5: ...ype Round Type A B C 30 30 SS 30 DI 6 t1 8 6 t1 8 5 8 3 4 2 40 40 SS 40 DI 8 t1 8 8 t1 8 3 60 60 SS 60 DI 12 t3 8 12 t3 8 2 3 1 2 80 80 DI 16 t3 8 16 t3 8 1 4 3 4 100 100 DI 20 t1 4 20 t1 4 3 3 8 5 1...

Страница 6: ...und welding to weld the base assembly and make sure that the bolt holes on the right and left sides are symmetrical KNR DI Models KNR Models KNR Model Install Reinforcing Rib Install to Plane Surface...

Страница 7: ...lt Base assembly Knocker Bolt set Upper nut Lower nut Spring washer 1 Washer Bolt Base assembly Hanging metal fittings Wire assembly The wire assembly is an option Shackle Wire assembly Exhaust port o...

Страница 8: ...ng another pipe the length of the tube from the branch point to each Knocker should be equal Avoid extreme bending and adding extra lines It may affect operation and impact force especially in units f...

Страница 9: ...ocker Relay tube Dummy tube 4 TUBE LENGTH OF RELAY SYSTEM PIPING AND AIR PRESSURE In relay system piping compressed air in the relay tube is also used for operation air of the Knocker Accordingly the...

Страница 10: ...into the Knocker 4 Is there any abnormal wear on the cylinders or pistons 5 Is there any spring damage 6 Is there any damage to safety wire assembly Replacement Period For Consumables Replace consumab...

Страница 11: ...n is worn Replace the piston The mushroom valve is worn or damaged Replace the mushroom valve Specifications List of Models Model KNR Working Pressure PSI Stroke Cycle cycle min Air Consumption cf cyc...

Страница 12: ...1 88 2 36 1 4 NPT 8 73 1 11 0 67 100 DI 6 89 8 19 0 78 2 14 1 97 10 63 0 83 F L E C M ST D H I G A O J K L E C M D G A O J K K ST L M M N O W Tube Size 1 8 NPT 1 4 1 8 1 73 0 23 1 11 0 86 1 4 1 8 2 1...

Страница 13: ...Pneumatics Minneapolis MN 55432 USA 1 800 233 7109 P 763 574 1820 F 763 574 1822 email solimar solimarpne com Solimar Solimar USA and the Radial Ridge Design are trademarks of Solimar Pneumatics Sinc...

Отзывы: