background image

Power input. 
 

1. 

Batteries

 

– use the alkaline 1.5V batteries only. The recharegeable batteries with 1.2V are not sufficient. If 

you use the rachargeable batteries which are partially discharged, the display may be difficult to read and the 
device will think that the batteries are completely discharged.

 

2. 

USB cabel

 

– with this cable you can´t recharge the batteries. It is used for direct powering of the device. 

There is no danger to destroy inserted batteries.  Plug the cable to the USB charging adapter 5V DC and then 
connect it to the device. No matter the output current.

 

 
Note: 

 

1.  To achieve an accurate reading (especially for the first time of using), user should ensure there is no residue 

inside the chamber before starting a new alcohol test. If there is residue left, the machine will take about 2 
minutes to warm up the sensor & chamber when user presses the 

CLEAN

 key.  

2.  After any 5 consecutive tests, allow the device to rest for 2 minutes. 
3.  When the product is unused, please store in a dry environment. 
4.  When batteries are low for alcohol testing, 

“LOB” flashes and then return to Real Time Clock mode. Please 

replace the batteries immediately. 

5.  If th

e difference between two successive reading is >0.1‰BAC 

(0.05mg/l or 0.01% BAC)

, you should repeat the 

test. 

6. 

Don´t block the gas outlet during the breath sampling, otherwise the reading will be affected. 

7.  After two minutes of inactivity, the analyzer goes into the sleep mode. For a total shut down, please remove the 

batteries. 

 

Storage and handling: 
 

1.  When the product is left unused, please store in a dry environment. 
2.  When low battery indicater flashes, the reading is not valid, please replace the batteries immediately or use 

included USB cable. 

3.  This is an instrument for breath alcohol concentration, you should avoid drops from heights. 
4.  Please ask for the recalibration from your nearby service centre if such kind of abnormal impact occurred. 
5.  Recalibration: According to the international standard (e.g. DIN31051), all measurement instrument should be 

recalibrated every 6 months. 

 

Product specifications: 

 

 

 

1. 

Display Range: 

0.10 ~ 3.

0 ‰ BAC  

2. 

Memory: 

10 memories 

3. 

Power Input: 

3*1.5V 

Alkaline

 batteries or USB cable (included) 

4. 

Display: 

Graphic & Digital display with Bi-color backlighting 

5. 

Real time clock power save mode: 

2 minutes after any key in 

6. 

Breath sampling: 

About 7 seconds continuous breath sample 

7. 

Dimensions: 

61*123*27 mm 

8. 

Weight: 

78g (without batteries) 

9. 

Alert level calibrated: 

0.2‰ BAC 

10. 

Agency Approval: 

CE 

11. 

Accessories: 

2 pcs blowing tubes 

12. 

Operating temperature: 

0

 - 40

 

 
The 1T04 Digital Alcohol Analyzer should be used as a general guide to the level of alcohol in your body. 
 
Many factors (e.g. environment gas residue, smoke & various smell in human mouth, etc

…) may affect the BAC level, 

so the Readings are For Reference Only. Neither the reseller nor manufacturer accept any liability arising from the use 
of this unit. DO NOT drink before you drive! Specifications are subject to change without notice. 

 

 

Отзывы: