background image

2

MANUAL -  PIR/PIRL - 04/2016

WWW.SOLIDE.COM

General

• 

The telescopic PIR and PIRL platforms are foldable, height-adjustable platforms that can be used by a single 

operator.

• 

They comply with French safety decree no. 2004-924 of September 1, 2004. 

• 

They have a maximum safe working load of 150 kg and a maximum working height of 3.5 m (PIRL) or 4.5 m 

(PIR).

• 

The platforms are height-adjustable thanks to a system of two sliding ladders.

• 

They are equipped with two wheels, allowing the platform to be moved easily and safely.

• 

The platforms are also equipped with two stabilizers

Technical characteristics

Ref.

Rungs*

Platform height

Working height

Folded dimensions

Weight

PIRL0406

4 to 6 rungs

0.90 to 1.50 m

0.90 to 3.50 m

2.20 x 0.92 x 0.42 m

25.6 kg

PIR0710

7 to 10 rungs

1.65 to 2.50 m

1.65 to 4.50 m

2.95 x 0.92 x 0.42 m

33.8 kg

Recommendations

• 

Make sure that you are sufficiently fit and well to use a platform. If you take any medication that might affect 

your alertness, or if you have taken alcohol or drugs, it is dangerous to use an extension ladder or stepladder.

• 

After receipt and before use, check that all parts are present and functioning correctly.

• 

At the start of each work day, check that the platform has not been damaged and that it can be used safely 

before starting to use it.

• 

If the platform is used for business purposes, a periodic inspection is mandatory.

• 

NEVER use a damaged platform.

• 

Make sure that the platform is suited to the intended task.

• 

Before each use, clear the platform of any deposits, such as fresh paint, oil or snow.

• 

To prevent them from sliding or tipping, platforms must always be positioned on a stable, horizontal and 

non-slippery surface.

• 

NEVER move a platform if someone is on it or if it is in a raised position.

• 

Before use, check that there is no risk of electrocution. Aluminium platforms conduct electricity, so you should 

always maintain a safe working distance from electrical wires and regularly check that the flexible cables of 

electrical devices are undamaged.

Отзывы: