background image

3333    

Contents 

Item

Item

Item

Item    

Page

Page

Page

Page    

Safety and Installation Instructions 

2 & 3 

Introduction 

Un Pack 

Key Features 

Block Diagram 

Specifications 

Front Panel Description 

Rear Panel Description 

Installation 

10 - 12 

Setting Up and Operation 

13 

Synchronisation 

14 

Frequently asked Questions 

15 

 

 

Conformity & Warranty 

    

 
 
 

CAUTION:  TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). NO USER-SERVICEABLE 
PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL 
 
CAUTION:  RISK OF ELECTRIC SHOCK. THIS EQUIPMENT HAS MORE THAN ONE POWER CORD. TO REDUCE THE RISKS OF 
ELECTRIC SHOCK DISCONNECT BOTH POWER SUPPLY CORDS BEFORE SERVICING 

 
The lightning flash with arrowhead symbol, within equilateral triangle, is intended to alert the user to the 
presence of un-insulated “dangerous voltage” within the product’s enclosure that may be of sufficient 
magnitude to constitute a risk of electric shock to persons. 
 

The exclamation point within an equilateral triangle is intended to alert the user to the presence of 
important operating instructions and maintenance (servicing) instructions in the literature accompanying 
the appliance. 
 

Important Safety Information

Important Safety Information

Important Safety Information

Important Safety Information    
 
This apparatus has no mains switch or other user-operated  control for disconnecting the AC mains power. The mains 
plugs or the appliance couplers (IEC sockets) are used as the disconnect devices. Either device must remain readily 
operable and accessible when the apparatus is installed for use. 
 
This unit includes thermally resettable fuses that are integral to the power supply circuitry, but the unit must always 
be powered from a supply fitted with an HRC type (High In-Rush Current) fuse with a rating of 1 A.

 

Important Safety Precautions

Important Safety Precautions

Important Safety Precautions

Important Safety Precautions    

Содержание XLogic SDI-MADI

Страница 1: ...XLogic SDI MADI This is SSL Installation and User Guide XLogic SDI MADI www solid state logic com ...

Страница 2: ...pparatus is fitted with a universal power supply approved and certified for operation in this apparatus There are no user replaceable fuses An external over current protection device is required to protect the wiring to this apparatus This protection device must be installed according to current wiring regulations In certain countries this function is supplied by use of a fused plug If an extensio...

Страница 3: ...that may be of sufficient magnitude to constitute a risk of electric shock to persons The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating instructions and maintenance servicing instructions in the literature accompanying the appliance Important Safety Information Important Safety Information Important Safety Information Importan...

Страница 4: ... of Please include your original proof of Please include your original proof of Please include your original proof of purchase when initiating the claim purchase when initiating the claim purchase when initiating the claim purchase when initiating the claim Within the EU Within the EU Within the EU Within the EU Pursuant to the Solid State Logic Terms and Conditions under European consumer law the...

Страница 5: ...chable sample rate convertors the SDI MADI is designed to reliably and seamlessly integrate into any broadcast environment where SDI embedded audio channels require format conversion This manual covers the XLogic SDI MADI s connections and indications including its various options for synchronisation and external control Please keep the manual in a safe place once you have installed the XLogic SDI...

Страница 6: ...audio output via 37 pin D Sub Dual 64 Ch MADI digital audio output via ST Multimode Optical and Coax Front Panel LED status indication for PSU SYNC SRC and SDI Lock Comprehensive sync options Wordclock AES Black and Burst SDI1 4 Wordclock and AES sync outputs On board sample rate convertors SRCs enabled locally or remotely via GPI Dual power supplies with separate IEC mains connectors Optional 19 ...

Страница 7: ...ith AES3 1992 AES3 AUDIO OUTPUTS GPIO PORT Connector output impedance 37 way female Dsub 32 x 75 Ω unbalanced GPIO port connector 9 pin female Dsub Format Compliant to AES3 1992 Input functions 4 x SRC select short to ground Sampling frequency 48 kHz nominal Output functions 4 x SRC status open collector MADI AUDIO OUTPUT POWER SUPPLY Connector output impedance coaxial BNC socket 75 Ω Type 2 x ind...

Страница 8: ... Selection Down Latches Locks Sync To Chosen Source SRC Control SRC Control SRC Control SRC Control Four 2 position toggle switches controlling the four 16 channel output SRCs The switch also enables external GPI control of each SRC PSU Status PSU Status PSU Status PSU Status Two bi colour LEDs confirming the current status of each PSU The LEDs are green in normal operation and flash red if a PSU ...

Страница 9: ...x BNCs SDI video active loop through outputs 1 to 4 4 x BNCs SDI video active loop through outputs 1 to 4 4 x BNCs SDI video active loop through outputs 1 to 4 4 x BNCs internally illuminated red Co Co Co Co axial MADI output BNC axial MADI output BNC axial MADI output BNC axial MADI output BNC 3 9 RS RS RS RS 422 port 422 port 422 port 422 port 9 pin female Dsub AES3 outputs AES3 outputs AES3 out...

Страница 10: ...ing both PSUs the two AC inlet cables should be connected to mains circuits which are as independent of each other as possible If redundant operation is not required only one AC supply cable need be connected either AC inlet may be used Fuses And Ratings Fuses And Ratings Fuses And Ratings Fuses And Ratings Each of the SDI MADI s PSUs has an internal resettable fuse for PSU protection These fuses ...

Страница 11: ...ront or rear of the rack and greatly simplifies wiring Pin Output SDI Source Audio Ch s Pin Output SDI Source Audio Ch s 1 AES 1 SDI 1 Ch s 1 2 20 AES 3 SDI 1 Ch s 5 6 2 AES 2 Ch s 3 4 21 AES 4 Ch s 7 8 3 AES 5 Ch s 9 10 22 AES 7 Ch s 13 14 4 AES 6 Ch s 11 12 23 AES 8 Ch s 15 16 5 AES 9 SDI 2 Ch s 1 2 24 AES 11 SDI 2 Ch s 5 6 6 AES 10 Ch s 3 4 25 AES 12 Ch s 7 8 7 AES 13 Ch s 9 10 26 AES 15 Ch s 1...

Страница 12: ...tical connection or vice versa for a redundant copper connection RS RS RS RS 422 Port 422 Port 422 Port 422 Port The rear panel includes an RS 422 port on a 9 pin female Dsub connector This connector has no function at this time SDI Input MADI Channels SDI 1 1 to 16 SDI 2 17 to 32 SDI 3 33 to 48 SDI 4 49 to 64 GPIO Port GPIO Port GPIO Port GPIO Port A GPIO General Purpose Input Output port is avai...

Страница 13: ...y also ensure that the word blocks in the data are phase locked exactly to the reference clock The SDI MADI allows the user to select a reference clock source to suit the infrastructure of the facility and the nature of the transfer process See following section on Synchronisation GPIO Control GPIO Control GPIO Control GPIO Control As the SDI MADI could be installed in a central control room or ou...

Страница 14: ... SDI Inputs Sync To The SDI Inputs Any of the four SDI inputs may be used to reference the audio outputs Each two channels of embedded audio in an SDI stream is essentially compatible with an AES3 word format at a sample frequency of 48 kHz and thus this frequency may be extracted and used as the SRC wordclock in the same way as an AES3 sync source If one or more pairs of audio channels in an SDI ...

Страница 15: ...e Converters for Q What are the Sample Rate Converters for Q What are the Sample Rate Converters for A In the traditional sense Sample Rate Converters SRC do as they say convert an incoming or outgoing audio source from one sample rate to another In the case of SDI MADI the SRCs perform two functions a The sample rate converters compensate for any minor frequency differences between the incoming S...

Страница 16: ...XLogic SDI MADI This is SSL www solid state logic com SSL Part No 82B4HM01A 82B4HM01A 82B4HM01A 82B4HM01A ...

Отзывы: