background image

 
 

Copyright 2013, Solexy USA, LLC

 

 

           IOM00038-07 

10178 International Blvd. 
Cincinnati, Ohio 45246 
Phone: 513-860-5465 
Fax:     513-860-5464 
www.solexy.net 

AXF/AXN 

Explosion Proof Antenna Coupler for use in 

MSHA-approved Mining Machines or Systems 

Installation & Operation Manual 

 

 
 
 
 
OVERVIEW 

 
The Solexy AXF/AXN explosion proof antenna coupler is an integrated protection device that facilitates radio 
antenna installation in hazardous areas.  The patented (7,057,577) AXF/AXN coupler features a barrier circuit 
which blocks power voltage in the event of a radio transmitter/receiver fault.  The circuit is encapsulated and 
housed in an explosion-proof stainless steel body.  By utilizing the coupler with a certified radio enclosure and 
limiting your output power per local regulations, your radio system may be easily approved for hazardous area 
use with most passive antennas. 
 
The information in this manual is intended to assist with equipment design and system approval. 
 
 

MSHA INTRINSIC SAFETY EVALUATION INFORMATION 
 

MSHA File Number: 

 

18-ISA080002-0 

 
The AXF is accepted for use in an MSHA-approved mining machine or system.  See applicable control drawing 
(below) for Conditions of Use. 
 
 

INSTALLATION 

 
For proper installation, see the applicable control drawing (attached): 

Drawing 

Coupler Description 

Model 

DC00037 

RP-SMA female antenna connector with 1-1/8-12 UNF thread 

AXFSS 

DC00040 

N female antenna connector with 1-1/8-12 UNF thread 

AXNSS 

 
1.  Feed the radio connection cable through the enclosure conduit entry.  Do not attach to radio at this time. 
2.  Screw coupler into enclosure following local electrical code (US MSHA requires 5 thread engagement). 
3.  Attach radio connection to radio output or lightning surge suppressor. 
4.  Attach antenna or antenna cable to antenna connector. 
 
 

SPECIFICATIONS  

Ambient Temperature Range 

-40

C to +85

C (subject to end product evaluation) 

Maximum Fault Voltage 

250 VDC, 250 VAC @ 60 Hz Max 

Maximum Radio Power Output 

2 Watts (subject to end product evaluation) 

Maximum Capacitance 

5.64 nF 

Frequency Range 

25 to 6000 MHz 

Impedance 50 

Ohms 

Approximate Signal Attenuation (1) 

Model AXF 

Model AXN 

425 MHz 

0.3 dB 

0.3 dB 

920 MHz 

0.6 dB 

0.6 dB 

2.4 GHz 

1.3 dB 

1.5 dB 

5.8 GHz 

4.8 dB 

3.9 dB 

(1) Values shown for 18” (457mm) coaxial cable and standard RP-SMA connectors (no adapter). 

    

 