background image

18 

 

 

 

 

-Fan Mode

 : When the unit is in Fan Mode, the Fan Mode light will turn on. Fan Mode operates the 

unit just like a fan and circulates air throughout the room without any additional cooling.  

-Dry Mode 

: When the unit is in Dry mode, the Dry mode light will turn on. Dry mode operates the 

unit as an evaporative dehumidifier to remove excess moisture from the room. Use this feature when 
there is excess humidity in the air.

 

7) 

Auto-on Delay Timer 

- To program the Auto-on timer, press the 

DELAY TIMER 

button when the 

unit is powered off. Press the ▲ or ▼ buttons to set the desired time (1-24 hours) for the unit to 
automatically turn on.  

Auto-off Delay Timer 

- To program the Auto-off Timer , press the 

DELAY

 

TIMER 

button when the unit is powered on.  Press the ▲ or ▼ buttons to set the desired timer (1-24 

hours) for the unit to automatically turn off.   

8) 

Check Filter 

- After the unit is on for 250 hours, the 

CHECK FILTER 

light will turn on to remind you 

to clean the filter. Press the 

FILTER RESET 

button once the filter has been cleaned to turn the light  

off. 

9) 

Signal Receiver

- Point the remote control to the air conditioner when sending instruction to the unit. 

10) 

Exhaust Control 

- The Exhaust control allows the air conditioner to re-circulate inside air when it is 

set to CLOSED. When it is set to OPEN the air conditioner exhaust air outside and brings in fresh 
air. Use the CLOSED position when maximum cooling is needed. OPEN removes stale inside air 
and replaces it with fresh air.  

 

 

 

OPERATING YOUR AIR CONDITIONER 

Содержание WCM1-08E-01

Страница 1: ...Electronic Casement Window Air Conditioner Operating Instructions Model WCM1 08E 01 8 000 BTU...

Страница 2: ...is owner s manual carefully Store this manual in a safe place for future reference Your safety and the safety of others is very important to us Please pay attention to all safety messages outlined in...

Страница 3: ...back of the unit Model WCM1 08E 01 Power Supply Ph V Hz 1 115V 60Hz Dehumidifying Capacity Pints Day 34 8 Rated Cooling Capacity BTU hr 8 000 Cooling Power Input Watts 762 Rated Current Cooling Amper...

Страница 4: ...esponsibility to provide proper and adequate receptacle wiring installed by an electrician ELECTRICAL REQUIRMENTS A 115 volt 103 5 minimum 126 5 maximum 60 Hertz AC only 15 ampere fused electrical sup...

Страница 5: ...label when checking electrical requirements Be sure the air conditioner is properly grounded To minimize shock and fire hazards proper grounding is important The power cord is equipped with a three pr...

Страница 6: ...nd or to any exposed metal The test and reset buttons on the LCDI Plug are used to check if the plug is functioning properly To test 1 Plug power cord into wall outlet The LED light will turn on 2 Pre...

Страница 7: ...r hand drill Knife and scissors Pencil PREPARING FOR INSTALLATION WARNING Failure to adhere to the following precautions could result in personal injury and product damage Because this unit weighs ove...

Страница 8: ...al strip Sash seal 8 Safety bracket 1 9 11 Screw 2 1 2 2 or Screw 1 3 4 2 or Screw 1 2 12 Screw 3 4 6 13 Screw 3 4 self threading 7 14 Window locking bracket 1 15 Plastic window panel 1 16 Side channe...

Страница 9: ...ne 8 11 16 inches from window jamb NOTE If any sash stop protrudes more than 1 inch from the side window jambs the 8 11 16 inch measurement must be increased accordingly Screen and storm window frames...

Страница 10: ...atform assembly with platform tab against inside of window track and attach it to window jamb Use appropriate length screws Items 9 11 in Preparing For Installation 7 Adjust platform assembly so that...

Страница 11: ...er Insulation Board over the Plastic Window Panel and firmly press and hold for 5 seconds FIG 12 1 12 1 Weather Insulation Board Installation NOTE The Weather Installation Board adds an extra layer of...

Страница 12: ...retaining screws from the front frame 2 Press firmly on each side of the metal case close to the front approximately 2 3 of the way down 3 While pressing on the sides of the metal case gently pull th...

Страница 13: ...sh and the window glass as shown right 19 Use the window locking bracket to lock the inner window sash to the base of the outer window sash Use one 8x3 4 inch screw or 8 32x3 4 inch self threading scr...

Страница 14: ...t hole locations that will create a 45 degree angle between the platform and the support brace Try the assembly in the window to determine if the platform will rest properly and allow the proper slope...

Страница 15: ...the cutting line with a fine tooth saw Remove any burrs with a file 9 Fasten the side channels to the sides of the unit using three screws Item 17 per channel Make sure hook ends of channels face towa...

Страница 16: ...and the cabinet side channels are against the top and side window jambs Side channels should overlap side window jambs equally 14 Drill two 9 64 inch diameter pilot holes in the top window jamb in li...

Страница 17: ...Dry Auto Mode Press Mode button repeatedly to cycle to Auto mode The unit will automatically run between Cool and Fan based on current room temperature Sleep Mode Press the SLEEP button to enter the S...

Страница 18: ...program the Auto off Timer press the DELAY TIMER button when the unit is powered on Press the or buttons to set the desired timer 1 24 hours for the unit to automatically turn off 8 Check Filter After...

Страница 19: ...NG INSTRUCTIONS Using the Remote Control MODE SLEEP FAN HIGH FAN MED FAN LOW CHILD LOCK ENERGY TIMER C F MYTEMP MODE SAVER LCD Display Battery Size AAA NOTE Do not mix old and new batteries or differe...

Страница 20: ...rating the same temperature until the sleep mode is turned off 6 ENERGY SAVER Press the ENERGY SAVER button to turn on Energy Saver mode When the unit is in Energy Saver mode the energy saver light wi...

Страница 21: ...g of the circuit breaker The fan will continue to run during this time AIR CONDITIONER FEATURES 4 WAY DIRECTIONAL LOUVERS Error Code Error Code Description Solution E2 Room temperature sensor failure...

Страница 22: ...inet Cleaning To clean the air conditioner cabinet Unplug the air conditioner to prevent shock or a fire hazard The cabinet and front panel of the air conditioner may be dusted with an oil free cloth...

Страница 23: ...ice technician TROUBLESHOOTING The Air Conditioner does not cool as it should Airflow is restricted The temperature control may not be set correctly The air filter is dirty The room may be too warm Co...

Страница 24: ...lted outside For proper water drainage make sure the air conditioner is slightly tilted downward from the front of the unit to the rear Water collects in the base pan Moisture removed from the air is...

Страница 25: ...rmal wear and tear Warranty service must be performed by a qualified HVAC contractor Soleus Home Comfort maintains a centralized service network to provide parts and assist in resolving service proble...

Отзывы: