background image

1

 

 

1. 

ON/OFF 

- Press the        button to turn the A/C on or off. When the unit is turned off, the Timer function 

will be cancelled. The set temperature will be saved. 

 
2.   

MODE SELECTION 

- Press the MODE button repeatedly to cycle between the different modes: Auto, 

Cool, Dry (Dehumidifier), and Fan. 

 
3.   

TEMPERATURE SETTING 

- Press the 

▼ 

button to decrease the temperature when the unit is on. 

Stop pressing the button when the desired temperature is displayed. Temperature range is 61

F-90

F. 

      Press the 

 button to increase the temperature when the unit is on. Stop pressing the button when 

the desired temperature is displayed. Temperature range is 61

F-90

F. 

 
4. 

FAN 

- Press the FAN button to turn on the fan mode. 

      FAN HIGH –Press this button to set the fan speed to high. Can be used in COOL or FAN mode. 
      FAN MED –Press this button to set the fan speed to medium. Can be used in COOL or FAN mode. 
      FAN LOW –Press this button to set the fan speed to low. Can be used in COOL or FAN mode. 
 
5. 

SLEEP MODE 

- Sleep mode can be activated under Cool mode, Dry mode, Auto mode, and Fan 

mode. Press the SLEEP button on the remote control, When in SLEEP mode, the fan will run on low to 
keep fan noise at a minimum. The temperature setting will gradually increase to 2°F above the original 
set temperature for each of first 2 hours. The unit will keep operating the same temperature until the 
sleep mode is turned off. 

 
6.   

ENERGY SAVER 

-  Press the ENERGY SAVER button to turn on Energy Saver mode. When the unit 

is in Energy Saver mode, the energy saver light will turn on. Selecting Energy Saver mode will cycle 
the fan off and on with the compressor to limit energy consumption. Use this feature when the room is 
unoccupied and a greater range of room temperature is acceptable. 

 

7. 

TIMER

 - Press the TIMER button when the unit is off to set up the Auto-on timer. The hour indicator on 

the digital display will start flashing. Press the 

  or  

  button to set timer within 1-24 hours.  

      Press the TIMER button when the unit is on to set up the Auto-off timer. The hour indicator on the digi-

tal display will start flashing. Press the 

  or  

  button to set timer within 1-24 hours. To cancel the 

timer, press the TIMER button repeatedly until the timer mode is off. 

 
8. 

°C 

/

°F - 

Press the 

°C 

/

°F 

button to switch the temperature between Celsius and Fahrenheit. 

 

9. 

MYTEMP MODE

 - Press the MYTEMP MODE button to change the thermostat sensor from the air 

conditioner to the remote location. When Mytemp mode is activated, current set temperature will flash 
3 seconds on digital display. The air conditioner will cool the area depending on the location and set 
temperature of the remote control. Take the remote control with you so the air conditioner cools the 
room to your location. 

 
10.  

CHILD LOCK

 - Press this button to lock/unlock the remote control buttons. 

  
 
 
 

REMOTE CONTROL OPERATING INSTRUCTIONS  

Содержание TTWM1-10-01

Страница 1: ...10 000 BTU Electronic Through the Wall Air Conditioner Operating Instructions Model TTWM1 10 01 3058080...

Страница 2: ...er s manual carefully Store this manual in a safe place for future reference Your safety and the safety of others is very important to us Please pay attention to all safety messages outlined in this o...

Страница 3: ...rrent detec tion device designed to reduce the risk of fire Please refer to the for details In the event that the power supply cord is damaged it cannot be repaired it must be replaced with a cord fro...

Страница 4: ...cted to ground or to any exposed metal The test and reset buttons on the LCDI Plug are used to check if the plug is functioning properly To test 1 Plug power cord into wall outlet 7KH OLJKW ZLOO WXUQ...

Страница 5: ...efer to the rating label on the back of the unit Model TTWM1 10 01 Power Supply Ph V Hz 1 115V 60Hz Dehumidifying Capacity Pints Day Rated Cooling Capacity BTU h 10 000 Cooling Power Input Watts 943 R...

Страница 6: ...be heard due to refrig erant passing through evaporator during normal operation High Pitched Chatter Today s high efficient com pressors may have a high pitched chatter during the cooling cycle Vibrat...

Страница 7: ...round wire does not be come tangled 4 Seal Frame the unit as described in next page Actual Sleeve may differ from image shown above 1 Match the Plastic Grille on back of the sleeve 2 Secure the Screw...

Страница 8: ...in this manual 1 Install the 1 x 1 1 2 x 84 long Stuff Seal between the wall sleeve and the unit A flat bladed screwdriver or putty knife is recommended 2 Assemble the Trim Frame by inserting the top...

Страница 9: ...fan speeds High Me dium and Low 6 Mode Selection Press the MODE button repeatedly to cycle between the different modes Cool Fan Dry and Auto Cool Mode When the unit is in Cool mode the Cool light will...

Страница 10: ...filter Press the FILTER RESET button once the filter has been cleaned to turn the light off 9 Sleep Mode Press the SLEEP button to enter the Sleep mode the fan will run on low to keep fan noise at a...

Страница 11: ...ERATING INSTRUCTIONS Using the Remote Control MODE SLEEP FAN HIGH FAN MED FAN LOW CHILD LOCK ENERGY TIMER C F MYTEMP MODE SAVER Battery Size AAA NOTE Do not mix old and new batteries or different type...

Страница 12: ...ating the same temperature until the sleep mode is turned off 6 ENERGY SAVER Press the ENERGY SAVER button to turn on Energy Saver mode When the unit is in Energy Saver mode the energy saver light wil...

Страница 13: ...o run during this time 4 WAY DIRECTIONAL LOUVERS Direct air up down left or right throughout the room with the 4 way directional louvers Error Code Description Solution E2 Room temperature sensor Unpl...

Страница 14: ...ng To clean the air conditioner cabinet x Unplug the air conditioner to prevent shock or a fire hazard The cabinet and front panel of the air conditioner may be dusted with an oil free cloth or washed...

Страница 15: ...technician TROUBLESHOOTING The Air Conditioner does not cool as it should Airflow is restricted The temperature control may not be set correctly The air filter is dirty The room may be too warm Cold a...

Страница 16: ...he unit to the rear Water collects in the base pan Moisture removed from the air is draining into the base pan x This is normal for a short period in areas with low humidity and nor mal for a longer p...

Страница 17: ...the care and special handling provi sions in the instructions Damage to the finish of the case or other appearance parts caused by wear Damage caused by repairs or alterations of the unit by anyone o...

Отзывы: