 Wiring Requirement

Recommended Ground Method 

For your personal safety, this air conditioner must be grounded. This air conditioner is equipped with a 3 prong power 

supply cord with a grounded plug. To minimize the possibility of electrical shock, the cord must be plugged into a 3 prong 

outlet and grounded in accordance with all local codes and ordinances. If a 3 prong outlet is not available, it is the cus-

tomer’s responsibility to have a properly grounded 3 prong outlet installed by a qualified electrician. 

LCDI Power Cord and Plug 

This air conditioner is equipped with an LCDI (Leakage Current Detection and Interruption) power cord and plug as    

required by US National Electric Code 440.65. This cord consists of a length of shielded flexible cord with no termination 

on the load side and a LCDI attachment plug on the line side. 
 
The LCDI power cord and plug will remove the supply source via electrical disconnect (circuit trip) if the nominal current 

leakage between the cord shield and either load conductor exceeds a predetermined value. The cord will remain de-

energized until the devise has been manually reset. This is intended to reduce the risk of a fire in the power cord or  

combustible materials nearby. The cord shields are not grounded and they must be considered a shock hazards if     

exposed. The cord shield must not be connected to ground or to any exposed metal. 
 
The test and reset buttons on the LCDI Plug are used to check if 

the plug is functioning properly. To test the plug:  
1.  Plug power cord into a wall outlet 
2.  Press the TEST Button, the circuit should trip and cut all 

power to the air conditioner 

3.  Press the RESET button for use 
 
If a test is performed and the indicator light remains ON, the   

current leakage has been detected. Do not use the air           

conditioner or attempt to reset the LCDI Plug. Contact Customer 

Service for troubleshooting recommendations.  

ELECTRICAL REQUIREMENTS 

 3 

Electrical Shock Hazard 

Plug into a grounded 3 prong outlet. 
Do not remove the ground prong. 
Do not use an adapter 
Do not use an extension cord. 
Failure to follow these instructions can result in death, 

fire, or electrical shock 

The electrical ratings for your air conditioner are listed on the model and serial 

number label located on the front left side of the unit (when facing the front). 
 
Specific electrical requirements are listed in the chart below. Follow the      

requirements below for the type of plug on the power supply cord. 

Power Supply Cord 

It is the customer’s responsibility: 

• 

To contact a qualified electrician 

• 

To assure that the electrical installation is adequate 

and in conformance with the National Electrical Code, 

ANSI/NFPA 70 - latest edition, and all local codes and 

ordinances. 

Copies of the standards listed may be obtained from:

 

National Fire Protection Association 

One Batterymarch Park 

Quincy, Massachusetts 02269 

208~230 Volt (197.2 min. - 253 max.)

0-20 amps

20-amp time-delay fuse or

Use on single outlet circuit only

Содержание SG-WAC-15ESE

Страница 1: ...Electronic Window Air Conditioner Operating Instructions Models SG WAC 15ESE SG WAC 18ESE SG WAC 25ESE ...

Страница 2: ......

Страница 3: ...ead this owner s manual carefully Store this manual in a safe place for future reference Your safety and the safety of others is very important to us Please pay attention to all safety messages outlined in this owner s manual WARNING To reduce the risk of fire electrical shock or injury when using your air conditioner follow the following basic precautions 2 This is a safety alert symbol This symb...

Страница 4: ...xposed metal The test and reset buttons on the LCDI Plug are used to check if the plug is functioning properly To test the plug 1 Plug power cord into a wall outlet 2 Press the TEST Button the circuit should trip and cut all power to the air conditioner 3 Press the RESET button for use If a test is performed and the indicator light remains ON the current leakage has been detected Do not use the ai...

Страница 5: ...SUPPORT BRACKET WINDOW SASH SEAL SILLANGLE BRACKET TOOLS NEEDED Large Flathead Screwdriver Tape Measurer Adjustable Wrench or Pliers Pencil Level Socket Wrenches Phillips Head Screwdriver 25ESE 15 18ESE Non Hardware Packing List Window Air Conditioner AAA Batteries 2 Remote Control Top Mounting Rail Foam Top Mounting Rail Seal Strip Accordion Panels 2 Side Retainer 2 Window Sash Seal Foam Seal for...

Страница 6: ... BTU h Cooling Power Input Watts 1400 Heating Power Input Watts Rated Current Cooling Amperage 12 Rated Current Heating Amperage EER C O P 10 8 Noise Level db A Indoor Outdoor 58 64 CFM 480 Design Pressure PSIG H L Dimensions W x H x D 23 63 x 17 78 x 25 44 Package Dimensions W x H x D 28 28 x 19 97x 26 09 Net Gross Weight Lbs 110 129 Refrigerant Charge Oz 28 22 SG WAC 18ESE 1 230 208 60Hz 129 6 1...

Страница 7: ...to tilt enough for proper drainage See FIG 1 Prior to Installing the Air Conditioner 1 Check for anything that could block airflow Check the area outside of the window for things such as shrubs trees or awnings Check the inside area to make sure curtains drapes or blinds will not prevent proper airflow 2 Check the available electrical outlet The power supply must be the same as shown on the unit s...

Страница 8: ...air conditioner cabinet FIG 3 4 5 Remove the shipping screws from the top of the unit SG WAC 25ESE only and both sides of the cabinet if in stalled 6 Remove the two screws on the top of the chassis that hold the cabinet to the unit Hold the cabinet while pulling on the base of the chassis and remove the chassis from the cabinet FIG 5 7 Add two foam inserts to the holes on top of the cabinet where ...

Страница 9: ...le and bottom rail Do both sides FIG 8b PLASTIC FRAME WINDOW FILLER PANEL SIDE RETAINER 8 Once the window panels are correctly installed for 25K insert the washer head locking screws on the top rail and frame Do not tighten all the way at this time Allow the bottom frame to slide freely Placing the Cabinet Inside the Window 1 Open the window and place the cabinet in the middle of the window sill 2...

Страница 10: ...l 6 bolts securely Mark Left Right 1 2 Long Screws and Locknuts Sill Angle Bracket Flat Head Bolt Locknut 1 2 long screw and locknuts Extend the Accordion Panels 1 Carefully raise the window to expose the accordion panel and panel frame Loosen the locking screws so the accordion panels slide easily 2 Extend each panel to completely fill the width of the 3 Close window behind top angle 4 Set a lock...

Страница 11: ...nstalled through an outside wall as specified below IMPORTANT The side louvers must never be blocked NOTE All parts needed for Thru The Wall Installation are provided except a wood frame shims and 10 wood screws 10 1 long minimum Select a wall surface that 1 Does not support major structural loads such as the frame construction at ends of windows and under truss bearing points etc 2 Does not have ...

Страница 12: ...th the dry wall NOTE If wall thickness is 8 12 or more add aluminum flashing over the bottom of the frame opening to assure water is unable to enter the area between the inner and outer wall Prepare and Install the Cabinet 1 Slide the chassis from the cabinet Refer back to the REMOVE CHASSIS instructions and FIG 1 6 in the WINDOW MOUNTING SECTION 2 Place the cabinet into the opening with the botto...

Страница 13: ...NRY CONSTRUCTION 1 Cut or build a wall opening in the masonry wall similar to the frame construction refer to the THRU THE WALL installation for a wall thickness greater than 8 1 2 2 Secure the cabinet in place using masonry nails or masonry anchor screws Or build a frame using the instructions found in the THRU THE WALL installation section 3 Make sure the masonry above the cabinet is supported w...

Страница 14: ...ting To set the Auto on Timer press the DELAY button on the unit or remote control Each touch of the on the unit or the buttons on the remote will change the timer setting in 1 hour intervals The SET light will turn on while setting Auto off Timer When the air conditioner is on it can be set to automatically turn off in 1 24 hours To se the Auto off Timer press the DELAY button on the unit or remo...

Страница 15: ...the Fan to Low with the temperature set in the middle NOTE If the air conditioner is off and is then turned on while set to a Cool setting or if turned from a fan setting to a Cool setting it may take approximately 3 minutes for the compressor to start and cooling to begin Energy Saver Mode Controls the Fan On The fan will cycle on and off with the compressor This results in winder variations of r...

Страница 16: ...d Tear To minimize wear and tear on the air condi tioner always wait at least 3 minutes before changing modes This will help prevent the compressor from overheating and the circuit breaker from tripping Cabinet Cleaning To clean the air conditioner cabinet Unplug the air conditioner to prevent shock or a fire hazard The cabinet and front panel of the air conditioner may be dusted with an oil free ...

Страница 17: ...ce technician TROUBLESHOOTING The Air Conditioner does not cool as it should Airflow is restricted The temperature control may not be set correctly The air filter is dirty The room may be too warm Cold air is escaping The Cooling Coils are frozen Make sure there are no curtains blinds or furniture blocking the front of the air conditioner Lower the set thermostat tempera ture Clean the filter See ...

Страница 18: ...rainage make sure the air conditioner is slightly tilted downward from the front of the unit to the rear Water collects in the base pan Moisture removed from the air is draining into the base pan This is normal for a short period in areas with low humidity and nor mal for a longer period in areas with high humidity The Air Conditioner Display reads EP A Sensor has failed in the air conditioner Con...

Страница 19: ...by wear Damage caused by repairs or alterations of the unit by anyone other than those authorized by Soleus Interna tional Inc Freight and Insurance cost for the warranty service Filter and Accessories ALL WARRANTIES INCLUDING ANY IMPLIED WARRANTY OF MERCHANT ABILITY ARE LIMITED TO ONE YEAR DURATION OF THIS EXPRESS LIMITED WARRANTY SOLEUS INTERNATIONAL INC DISCLAIMS ANY LIABILITY FOR CONSEQUENTIAL...

Страница 20: ...66129903756 ...

Отзывы: