Model SG-CAC-08ESE SG-CAC-10SE SG-CAC-12SE
Страница 1: ...Electronic Casement Window Air Conditioner Operating Instructions Model SG CAC 08ESE SG CAC 10SE SG CAC 12SE ...
Страница 2: ...ead this owner s manual carefully Store this manual in a safe place for future reference Your safety and the safety of others is very important to us Please pay attention to all safety messages outlined in this owner s manual WARNING To reduce the risk of fire electrical shock or injury when using your air conditioner follow the following basic precautions 2 This is a safety alert symbol This symb...
Страница 3: ...Capacity Pints Day 31 2 Rated Cooling Capacity BTU hr 8 000 Cooling Power Input Watts 762 Rated Current Cooling Amperage 6 6 Cooling EER 10 5 Noise Level dB A High Med Low 56 54 52 CFM High Med Low 450 410 370 Power Plug Type NEMA 5 15P Product Dimensions W x D x H Inches 14 2 x 24 5 x 20 3 Product Weight Lbs 72 8 Refrigerant R 410A SG CAC 10SE 1 115 60 36 10 000 1052 9 2 9 5 60 58 56 550 510 470 ...
Страница 4: ... and Personal Injury Hazard Electrical ground is required on this appliance DO NOT ground to a gas line If a cold water pipe is interrupted by plastic non metallic gaskets or other insulating materials DO NOT use for grounding Check with a qualified electrician if you are in doubt as to whether the appliance is properly grounded DO NOT modify the power supply cord plug If it does not fit the outle...
Страница 5: ...S INTERNATIONAL HAS NOT CONDUCTED INDEPENDENT TEST TO THE INFORMATION AND THE SPECIFICATIONS PRESENTED HEREWITHIN PREPARING FOR INSTALLATION WARNING Failure to adhere to the following precautions could result in personal injury and product damage Because this unit weighs about 88 to 105 pounds it is recommended that you have someone help you when install your new unit and that you both use proper ...
Страница 6: ...6 PARTS LIST INSTALLATION ...
Страница 7: ...htly mark a line 8 11 16 inches from window jamb NOTE If any sash stop protrudes more than 1 inch from the side window jambs the 8 11 16 inch measurement must be increased accordingly Screen and storm window frames may also require adjustments to the measurement 3 Center platform assembly on the line with inside platform tab pressed against inside edge of window track Using the holes in the platfo...
Страница 8: ...atform assembly with platform tab against inside of window track and attach it to window jamb Use appropriate length screws Items 9 11 in Preparing For Installation 7 Adjust platform assembly so that outside edge is 3 16 inch lower than inside edge as shown right This ensures proper water drainage from the air conditioner 8 Level platform assembly from side to side Also make sure window track is l...
Страница 9: ...el seal into 2 equal lengths Remove protective backing and apply it to the rear side of cabinet side channels starting just below panel frame assembly Pinch off excess length so seal is even with the bottom of the cabinet side channel 14 To remove front 1 Remove the two front retaining screws from the front frame 2 Press firmly on each side of the metal case close to the front approximately 2 3 of...
Страница 10: ...ash and the window glass as shown right 19 Use the window locking bracket to lock the inner window sash to the base of the outer window sash Use one 8x3 4 inch screw or 8 32x3 4 inch self threading screw Drill 1 8 inch pilot hole 20 To replace the front First reconnect the coupler plugs make the exhaust control positioned through the front in the proper location Gently push the front into position...
Страница 11: ...lt hole locations that will create a 45 degree angle between the platform and the support brace Try the assembly in the window to determine if the platform will rest properly and allow the proper slope 3 16 inch lower on outside NOTE If you are planning to use a siding protec tion board see Step 6 on the outside of your house hold the board in place when testing the assembly in the window 2 Drill ...
Страница 12: ...ng enough to span 2 wall studs 7 Measure the height of the window opening from the top of the platform assembly Subtract 20 5 8 inches Mark this measurement on the plastic window panel along the longer side 8 Clamp the plastic window panel between a board and a work table and cut along the cutting line with a fine tooth saw Remove any burrs with a file 9 Fasten the side channels to the sides of th...
Страница 13: ...e and the cabinet side channels are against the top and side window jambs Side channels should overlap side window jambs equally 14 Drill two 9 64 inch diameter pilot holes in the top window jamb in line with the partially plugged holes in the panel frame Secure the panel fame to the window jamb with two 8 32x3 4 inch self threading screws If additional holding is necessary two screws may be used ...
Страница 14: ...hen handling the air conditioner be careful to avoid cuts form sharp metal fins on the front and rear coils NOTE The power supply cord on this air conditioner contains a current detec tion device designed to reduce the risk of fire Please refer to the section Operation of Current Device for details In the event that the power supply cord is damaged it cannot be repaired it must be replaced with a ...
Страница 15: ...e button will click when the RESET button engages 4 The power supply cord is now supplying electricity to the unit NOTE Do not use this device to turn the unit on or off Always make sure the RESET button is engaged for correction operation The power supply cord must be replaced if it fails to reset when either the TEST button is pushed or it cannot be reset A new one can be obtained from Soleus Ai...
Страница 16: ...n speeds High Medium low and Auto 6 Mode Selection Press the MODE Button repeatedly to cycle between the different modes Cooling Energy Saver Dehumidifier Fan and Auto mode 7 Auto on Timer To program the Auto on timer press the TIMER button when the unit is pow ered off Press the or buttons to change the timer to the desired amount of time 5 24 hours for the unit to automatically turn on Auto off ...
Страница 17: ... to the remote location The air con ditioner will cool the area depending on the location and set temperature of the remote control Take the remote control with you so the air conditioner cools the room to your loca tion 7 SLEEP MODE Press the SLEEP button to turn SLEEP mode on or off SLEEP mode is set to off automatically When SLEEP mode is selected the timer can be adjusted SLEEP mode is not ava...
Страница 18: ...To switch between the F or C settings press the MODE and buttons a the same time 11 DISPLAY LIGHTS Hold the and FAN buttons to turn the light s on the display ON or OFF This can be done when the unit is on or off 12 ENERGY SAVER MODE When the unit is in energy saver mode the Energy Saver light will turn on In Energy Saver mode the unit will turn off once the room is cooled to the user set temperat...
Страница 19: ...position when maximum cooling is needed OPEN removes stale inside air and replaces it with fresh air Direct air up down left or right throughout the room with the 4 way directional louvers 19 AIR CONDITIONER FEATURES OPERATING YOUR AIR CONDITIONER There is a 3 minute delay when cooling mode is engaged or disengaged This delay prevents the compressor from overheating and possible tripping of the ci...
Страница 20: ... cabinet Unplug the air conditioner to prevent shock or a fire hazard The cabinet and front panel of the air conditioner may be dusted with an oil free cloth or washed with a cloth dampened in a solution of warm water and mild liquid soap Rinse thoroughly with a damp cloth and wipe dry Never use harsh cleaners wax or polish on the cabinet front Be sure to wring excess water from the cloth before w...
Страница 21: ...ce technician TROUBLESHOOTING The Air Conditioner does not cool as it should Airflow is restricted The temperature control may not be set correctly The air filter is dirty The room may be too warm Cold air is escaping The Cooling Coils are frozen Make sure there are no curtains blinds or furniture blocking the front of the air conditioner Lower the set thermostat tempera ture Clean the filter See ...
Страница 22: ...llects in the base pan Moisture removed from the air is draining into the base pan This is normal for a short period in areas with low humidity and nor mal for a longer period in areas with high humidity The Air Conditioner Display reads AS A Sensor has failed in the air conditioner Contact customer service The Air Conditioner Display reads HS A Sensor has failed in the air conditioner Contact cus...
Страница 23: ...by wear Damage caused by repairs or alterations of the unit by anyone other than those authorized by Soleus Interna tional Inc Freight and Insurance cost for the warranty service Filter and Accessories ALL WARRANTIES INCLUDING ANY IMPLIED WARRANTY OF MERCHANT ABILITY ARE LIMITED TO ONE YEAR DURATION OF THIS EXPRESS LIMITED WARRANTY SOLEUS INTERNATIONAL INC DISCLAIMS ANY LIABILITY FOR CONSEQUENTIAL...