background image

 11 

 

REMOTE CONTROL OPERATING INSTRUCTIONS 
 

1) 

Power On and Off 

- If the unit is already on, press the 

POWER (

I/O

button on the remote while 

pointing the remote away from the unit. This will turn the remote on. If the unit is off, now press the 

POWER (

I/O

button once to manually turn the unit on. Press the Power button once more to turn the 

unit off.  When you press the 

POWER 

button the upper right square on the remote control LCD Dis-

play will light up. When in Air Conditioner and Auto mode, the selected temperature will appear on the 
remote control display. When the unit is in Fan mode and Dehumidifier mode you will see the “- -” 
icon instead of the set temperature. This shows that temperature selection is not available when the unit 
is in Fan or Dehumidifier mode. When the unit is in Fan mode you will see the “F*” icon instead of the 
set temperature on the control panel of the unit. 

2) 

Mode Selection 

- Press the 

MODE

 Button repeatedly to cycle between the different modes: Auto, 

Air Conditioner, Dehumidifier, and Fan only mode. The upper left square on the Remote control dis-
play will light up showing which mode is selected. In Air Conditioner mode the display will show 

COOL

”, in Dehumidifier mode the display will show “

DRY

”, in Fan mode the display will show 

FAN

”, and in Auto mode the display will show “

AUTO

”. 

3) 

Fan Speed 

- Press the 

FAN 

speed button to cycle through high, medium, and low fan speeds. The 

display on the remote control will show HIGH, MED, LOW under the “SPEED” label on the remote 
control LCD display. There is an additional 

auto 

speed setting that is enabled in only cooling mode. 

This speed is next setting after low when pressing the 

FAN 

speed button on the remote control. The 

speeds will cycle through in this order: 

High, Medium, Low, Auto

. Each change in speed will be asso-

ciated with a “beep” sound from the unit. The remote control will not display “AUTO” under the speed 
label. Once Auto fan speed is selected the unit will beep and there will not be a fan speed displayed on 
the remote control. 

4) 

Temperature Setting 

- When the unit is in Air Conditioner mode you can select your desired tem-

perature. Press the +or - to select your desired temperature setting. The temperature on the LCD display 
on the remote control will increase or decrease accordingly.  Pressing the - and + buttons simultane-
ously will change the temperature select between °F and °C.  

5) 

SLEEP MODE  

- To set Sleep mode, make sure the unit is in Air Conditioner mode. Press the 

SLEEP 

Button on the remote control, The display on the remote control will show the “SLEEP” icon on the 
remote control LCD display. When in 

SLEEP 

mode, the fan will run on low to keep fan noise at a 

minimum. When in Air Conditioner mode, the temperature setting will gradually increase to 2°F above 
the original set temperature for 6 hours.  After 6 hours the temperature setting will return to the set tem-
perature. When in Dehumidifier mode, the temperature will not change when Sleep mode is selected. 

6) 

CLOCK 

- To set the clock on the remote control, hold down either the 

MIN 

or 

HOUR 

button until the 

displayed time flashes on the remote control display. Change the minutes by pressing the 

MIN 

button 

and change the hours by pressing the 

HOUR 

button. Set the clock prior to programming the timer. 

7) 

TIMER 

- To program the timer, first press the 

T-ON 

button. Once 

T-ON 

is pressed the auto-on timer 

Fan Speed

 

High

 

Medium

 

Low

 

Auto

 

Remote control display

 

HIGH

 

MED

 

LOW

 

 

Unit control display

 

F3

 

F2

 

F1

 

FA

 

Содержание SE-PAC-08E9

Страница 1: ...8 000 BTU Portable Air Conditioner Operating Instructions V 130711 Model No SE PAC 08E9 Reference No KY 80E9 3092402...

Страница 2: ...ual in a safe place for future reference 1 Always place the unit on a level surface 2 Never use or store gasoline or other flammable vapor or liquid near this unit unless instructed by this manual 3 M...

Страница 3: ...or lower than the minimum operat ing temperature the air conditioner may not work properly PACKAGE CONTENTS MODEL NUMBER SE PAC 08E9 REFERENCE NUMBER KY 80E9 COOLING CAPACITY 8 000 BTU H DEHUMIDIFYING...

Страница 4: ...rounded and they must be considered a shock hazards if exposed The cord shield must not be connected to ground or to any exposed metal The test and reset buttons on the LCDI Plug are used to check if...

Страница 5: ...DIAGRAM Casters Louvers Remote Control Signal Receptor Control Panel on top Filter Compartment Remote Control Evaporator Air Intake Condenser Air Outlet Condenser Air Intake Drain Port Drain Hole Rub...

Страница 6: ...ass doors up to 7 ft long approximate length MOUNTING THE EXHAUST HOSE Choose a suitable location near a grounded electrical outlet and suitable window or door Remove packaging and locate components E...

Страница 7: ...and im ages show general directions for Soleus Air hose portable air conditioners WINDOW KIT INSTALLATION Optional Window Kit Adapter Extension Included The Window Kit Adapter Extension is an optiona...

Страница 8: ...crews A Do not tighten the Wing Nuts B all the way make sure they are somewhat loose 4 Now place the Sliding Track Panel D over the Track Screw A on Hose Panel C1 5 Next take the other Hose Panel C2 a...

Страница 9: ...mode The temperature indicator flashes to display the desired temperature setting After the temperature is set the unit will display this temperature setting until it is changed by the user The tem pe...

Страница 10: ...OL TIMER ON TIMER OFF LCD DISPLAY POWER BUTTON MINUTE SELECTER SLEEP BUTTON HOUR SELECTER TEMP SETTING MODE BUTTON FAN SPEED OPERATING THE UNIT USING THE REMOTE CONTROL Remote Colors may differ from t...

Страница 11: ...er low when pressing the FAN speed button on the remote control The speeds will cycle through in this order High Medium Low Auto Each change in speed will be asso ciated with a beep sound from the uni...

Страница 12: ...e ranges from 61 F 88 F 16 C 31 C 6 Select the desired fan speed by pressing the FAN button by using the Remote control NOTE During hot days the unit will cool the room most efficiently by setting the...

Страница 13: ...1 high to catch the water coming out of the condensate tank Connect the supplied drainage hose to the back of the unit to aid in drainage into the pan Once the condensate tank is drained the unit will...

Страница 14: ...ghly dried 4 If the filter is torn or unusable order a new filter by calling the customer service number on the warranty page of this manual Clean the unit Housing 1 Keep the unit from being exposed d...

Страница 15: ...ppearance parts caused by wear Damage caused by repairs or alterations of the unit by anyone other than those authorized by Soleus In ternational Inc Freight and Insurance cost for the warranty servic...