background image

 

 

 

 

 
 

BUCKET FULL INDICATOR

 

When the Internal Water Tank is full, the Bucket Full light will illuminate and the unit will automatically 
shut down. The air conditioner will resume normal operation once Internal Water Tank is emptied.

 

 

INTERNAL WATER TANK

 

When the room temperature is low and the indoor humidity is high, the air conditioner may not be able to 
evaporate some of the moisture fast enough. When this happens, the water will accumulate in an internal 
water tank inside the unit. The internal water tank holds approximately 1.5 liters of water. When this tanks 
becomes full, the unit will automatically shutdown and illuminate the Bucket Full indicator.

 

 

 
 

HOW TO INSTALL CONTINUOUS DRAIN OPTION: 

 

 

1.

 

Place the Portable AC on a level surface.

 

2.

 

Remove the cap on continuous drain port on the back of the unit to access the Continuous Drain Port.

 

3.

 

Thread a garden hose (not supplied) onto the accessible Continuous Drain Port.

 

4.

 

Lead Garden Hose to a floor drain and cut to length.

 

5.

 

Make sure that there are no kinks or knots in the garden hose (Fig 15.1).

 

6.

 

Turn on the unit and gravity draining will begin automatically.

 

 

 
 

Fig 15.1

 

MAINTENANCE

 

Содержание PSC-12HP-201

Страница 1: ...Portable Air Conditioner with Heat Pump 12 000 BTU 14 000 BTU OPERATING INSTRUCTIONS V170217 PSC 12HP 201 PSC 14HP 01 3058080...

Страница 2: ...n a safe place for future reference 1 Always place the unit on a level surface 2 Never use or store gasoline or other flammable vapor or liquid near this unit unless instructed by this manual 3 Mainta...

Страница 3: ...d setting These specifications are for reference only For actual data please refer to the rating label on the back of the unit If the environment temperature is higher than the max operating temperatu...

Страница 4: ...xposed metal The test and reset buttons on the LCDI Plug are used to check if the plug is functioning properly To test 1 Plug power cord into wall outlet the LED light will turn on 2 Press TEST Button...

Страница 5: ...Grille 9 Condensation Drain Hole 10 Exhaust Hose 11 Exhaust Hose Connector 12 Window Kit Adapter Grille 13 Window Kit Adapter 14 Optional Window Kit Adapter Extension 15 Window Kit Panel 16 Wing Nuts...

Страница 6: ...he unit in air conditioning dehu midification and heating modes When the unit is operating in Fan Mode no outdoor air exchange takes place The window kit and exhaust hose do not need to be installed w...

Страница 7: ...WINDOW KIT ASSEMBLY...

Страница 8: ...anels to fit the opening If necessary mark the kit and cut one end down to properly fit the opening 3 Twist the Exhaust Hose Connector over the discharge opening on the back of the unit and extend the...

Страница 9: ...on Your Window Kit also includes an optional security bracket that can be installed to prevent the window from being opened from the outside while a Window Kit is installed SECURITY BRACKET Single and...

Страница 10: ...until it is changed by the user The temperature indicator display shows temperature in Fahrenheit While the unit is plugged in but not powered on press and hold the and buttons for 3 seconds to switc...

Страница 11: ...LCD DISPLAY POWER BUTTON TIMER TEMP DECREASE TIMER TEMP INCREASE REMOTE LOCK BUTTON SLEEP BUTTON TIMER BUTTON TURBO COOL BUTTON C F SWITCH BUTTON MODE BUTTON FAN SPEED MY TEMP BUTTON REMOTE CONTROL...

Страница 12: ...mode icon will show on the remote control LCD display When in SLEEP mode the fan will run on low to keep fan noise at a minimum The temperature setting will gradually increase to 2 F above the origi n...

Страница 13: ...the MODE button until the dehumidifier mode indicator lights up on the control panel display 5 Temperature indicator displays room temperature NOTE The unit operates at low fan speed during dehumidifi...

Страница 14: ...the control panel display 4 Select the fan speed by pressing the FAN SPEED button NOTE It is not necessary for the exhaust hose and window kit to be installed to operate the unit in fan mode Sleep Mod...

Страница 15: ...inside the unit The internal water tank holds approximately 1 5 liters of water When this tanks becomes full the unit will automatically shutdown and illuminate the Bucket Full indicator HOW TO INSTAL...

Страница 16: ...e water will drain out automati cally 4 When the drain pan is full install the drain plug back onto the condensation drain hole to stop the water flow 5 Empty the drain pan 6 Repeat steps 2 5 until al...

Страница 17: ...n the unit Housing 1 Keep the unit from being exposed directly to the sun to prevent color fading 2 Clean the surface with a damp cloth and dry it with a soft towel Storing the Unit for an Extended Pe...

Страница 18: ...ly keeping it as short and free of curves as possible Check and remove anything obstructing air discharge During operation there is an unpleasant smell in the room Air filter is dirty Remove air filte...

Страница 19: ...SELF DIAGNOSIS The unit has a self diagnosis system to identify a number of malfunctions Error codes are displayed on the appliance display SELF DIAGNOSIS CODES...

Страница 20: ...rovi sions in the instructions Damage to the finish of the case or other appearance parts caused by wear Damage caused by repairs or alterations of the unit by anyone other than those authorized by So...

Отзывы: