BUCKET FULL INDICATOR
When the Internal Water Tank is full, the Bucket Full light will illuminate and the unit will automatically
shut down. The air conditioner will resume normal operation once Internal Water Tank is emptied.
INTERNAL WATER TANK
When the room temperature is low and the indoor humidity is high, the air conditioner may not be able to
evaporate some of the moisture fast enough. When this happens, the water will accumulate in an internal
water tank inside the unit. The internal water tank holds approximately 1.5 liters of water. When this tanks
becomes full, the unit will automatically shutdown and illuminate the Bucket Full indicator.
HOW TO INSTALL CONTINUOUS DRAIN OPTION:
1.
Place the Portable AC on a level surface.
2.
Remove the cap on continuous drain port on the back of the unit to access the Continuous Drain Port.
3.
Thread a garden hose (not supplied) onto the accessible Continuous Drain Port.
4.
Lead Garden Hose to a floor drain and cut to length.
5.
Make sure that there are no kinks or knots in the garden hose (Fig 15.1).
6.
Turn on the unit and gravity draining will begin automatically.
Fig 15.1
MAINTENANCE
Содержание PSC-12HP-201
Страница 7: ...WINDOW KIT ASSEMBLY...